Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.

Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Abstract Text:

    jan s bauerJan S Bauer,stefanie j krauseStefanie J Krause,christian j rossChristian J Ross,roland krugRoland Krug,julio carballido-gamioJulio Carballido-Gamio,eugene ozhinskyEugene Ozhinsky,sharmila majumdarSharmila Majumdar,thomas m linkThomas M Link,

    PURPOSE: To compare the precision and accuracy of 3.0-T and 1.5-T magnetic resonance (MR) imaging in the quantification of cartilage volume by using direct volumetric measurements as a reference standard. MATERIALS AND METHODS: The local animal experimentation committee did not require its approval for this study. Porcine knees were obtained from an abattoir. These specimens were used to optimize imaging parameters regarding effective signal-to-noise ratio (SNRE) and contrast-to-noise ratio (CNRE) for a fat-saturated spoiled gradient-recalled acquisition in the steady state (SPGR) sequence, a water excitation SPGR sequence, and a fast spin-echo sequence at 3.0 T and a fat-saturated SPGR sequence at 1.5 T. By using the optimized sequences, 18 specimens were imaged in less than 6 minutes per sequence. A fivefold repetition of measurements of four specimens was performed for precision analysis. Cartilage was segmented by using semiautomatic software to calculate the volume. After imaging, the cartilage was scraped off and the volume was measured directly by using a saline-displacement method to calculate accuracy. Precision and accuracy errors were calculated as the root-mean-squares of the single errors per specimen. RESULTS: SNRE and CNRE values, respectively, were highest for the water excitation sequence at 3.0 T (1.81 sec(-1/2) and 1.27 sec(-1/2)), followed by the fat-saturated SPGR sequence (1.52 sec(-1/2) and 1.07 sec(-1/2)). The fast spin-echo sequence and the fat-saturated SPGR sequence at 1.5 T had lower SNR(E) (1.27 sec(-1/2) and 0.59 sec(-1/2), respectively). Accuracy error for MR-based volume calculation at the femur was 5.0%, 3.0%, 21%, and 16% for the water excitation, fat-saturated SPGR, and fast spin-echo sequences at 3.0 T and the fat-saturated SPGR sequence at 1.5 T, respectively. CONCLUSION: MR imaging at 3.0 T was shown in our study to better quantify cartilage volume. SNRE and CNRE were substantially improved, resulting in significantly higher accuracy in determining cartilage volume.

    Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Publishing Authors By Initials

    js bauerJS Bauer,sj krauseSJ Krause,cj rossCJ Ross,r krugR Krug,j carballido-gamioJ Carballido-Gamio,e ozhinskyE Ozhinsky,s majumdarS Majumdar,tm linkTM Link,

    For similar animals: chordata: vertebrates: mammals: artiodactyla: swine research abstracts see: animals: chordata: vertebrates: mammals: artiodactyla: swine research

    PUBMED ID PMID:

    MEDLINE DATE:

    Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Journal Published:

    PUBLICATION TYPE: Research Support, N.I.H., Extr

    Journal: Radiology

    VOLUME: 241

    Page Numbers: 399-406

    Journal Abbreviation:

    ISSN: 0033-8419

    DAY: 3

    MONTH: Nov

    YEAR: 2006

    Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 401260

    Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Keywords Mesh Terms:

    KEYWORDS: Swine

    MESH TERMS: methods

    Chemical & Substance for Abstract: Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.

    AFFILIATION: Musculoskeletal and Quantitative Imaging Research, Department of Radiology, University of California, San Francisco, Calif., USA. jsb@roe.med.tum.de

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NIA

    GRANT: AG46905

    ACRONYM: AG

    MEDLINETA: Radiology

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Volumetric cartilage measurements of porcine knee at 15-T and 30-T MR imaging: evaluation of precision and accuracy Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News