Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy.

Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Abstract Text:

    aliza m thompsonAliza M Thompson,kazuo eguchiKazuo Eguchi,michael e reznikMichael E Reznik,samir s shahSamir S Shah,thomas g pickeringThomas G Pickering,

    OBJECTIVES: Increased arterial stiffness, common in end-stage renal disease patients, has been shown to affect the correspondence between oscillometric and mercury sphygmomanometer blood pressure readings. The purpose of this study was to validate an oscillometric home blood pressure monitor in an end-stage renal disease population and to determine the effect of arterial stiffness on its accuracy. METHODS: Blood pressure measurements were taken with the Microlife 3AC1-1PC (Microlife; Taipei, Taiwan), an oscillometric home blood pressure monitor, and a mercury sphygmomanometer in 33 patients as specified by the European Society of Hypertension Validation Protocol. Radial pulse wave analyses were also performed. RESULTS: On the basis of European Society of Hypertension criteria, the Microlife 3AC1-1PC received a passing score for systolic and diastolic blood pressures. On average, the oscillometric monitor overestimated diastolic blood pressure by 2.4 mmHg (P=0.005, SD=4.5 mmHg) and there was a trend towards overestimation of systolic blood pressure as well (1.3 mmHg, P=0.09, SD=4.4 mmHg). A positive correlation was found between arterial stiffness, as assessed by augmentation index and pulse pressure, and the diastolic blood pressure difference between the device and the mercury sphygmomanometer (r=0.54, P=0.003; and r=0.65, P=0.001, respectively). Diastolic blood pressure was negatively correlated with the diastolic blood pressure difference (r=-0.49, P=0.003). No significant relationship was found between the systolic blood pressure difference and augmentation index, pulse pressure or systolic blood pressure. CONCLUSION: The Microlife 3AC1-1PC was shown to accurately measure blood pressure in patients with end-stage renal disease. As arterial stiffness increased and diastolic blood pressure fell, diastolic blood pressure was increasingly overestimated.

    Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Publishing Authors By Initials

    am thompsonAM Thompson,k eguchiK Eguchi,me reznikME Reznik,ss shahSS Shah,tg pickeringTG Pickering,

    For similar equipment and supplies: diagnostic equipment: sphygmomanometers research abstracts see: equipment and supplies: diagnostic equipment: sphygmomanometers research

    PUBMED ID PMID:

    MEDLINE DATE:

    Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Journal Published:

    PUBLICATION TYPE: Validation Studies

    Journal: Blood pressure monitoring

    VOLUME: 12

    Page Numbers: 227-32

    Journal Abbreviation:

    ISSN: 1359-5237

    DAY: 3

    MONTH: Aug

    YEAR: 2007

    Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9606438

    Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Keywords Mesh Terms:

    KEYWORDS: Sphygmomanometers

    MESH TERMS: instrumentation

    Chemical & Substance for Abstract: Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy.

    AFFILIATION: Department of Medicine, Behavioral Cardiovascular Health and Hypertension Program and Division of Nephrology, Columbia University, New York, New York, USA. at2026@columbia.edu

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY: United States NCRR

    GRANT: RR00645

    ACRONYM: RR

    MEDLINETA: Blood Press Monit

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News