Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

[Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography]

[Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Abstract Text:

    r detreilleR Detreille,b sauerB Sauer,j p zabelJ P Zabel,t batchT Batch,x zhuX Zhu,a blumA Blum,r detreilleR Detreille,b sauerB Sauer,j p zabelJ P Zabel,t batchT Batch,x zhuX Zhu,a blumA Blum,

    PURPOSE: To determine the influence of 4 independent parameters on signal intensity and density measurements after injection of an arthrography-specific form of gadoterate meglumine and an iodinated contrast material for combined MR and CT arthrography. The parameters included: 1) variations of gadolinium and iodinated contrast agents within the mixture, 2) variations of concentration of the iodinated contrast agent, 3) variation of temperature of the mixture, 4) the type of MR pulse sequence acquired. MATERIALS AND METHODS: The study was performed on a CT using a phantom containing 47 different syringes. Ten separate mixtures of gadolinium and iodinated contrast agents were obtained, each with a 10% change in the respective proportion of each contrast agent. This was repeated 4 times for 4 iodinated contrast agents of different iodine concentration. Two control syringes, 4 mixtures containing 50% normal saline and 50% iodinated contrast material (one for each of the 4 concentrations of iodinated contrast material) and one with a mixture of 50% of normal saline and gadolinium contrast agent. For the MR acquisition, the syringes were separated into 4 groups for 4 phantoms. On a 1.5 T MR unit, SE T1W, FSE T2W, PD and 3D FIESTA sequences were acquired. All acquisitions were repeated 2 times, and a 3 different temperatures. RESULTS: The progressive increase in the proportion of gadolinium contrast in the solution was associated with a non-linear increase of signal on T1W, 3D FIESTA, and PD images. The signal intensity reached a plateau at concentrations between 40-60%. Signal variations on the 3D FIESTA sequence were significant. On T2W images, there was an increase of measured signal intensity at low gadolinium concentrations. On CT, there was a linear relationship between density measurements and dilution of gadolinium. The progressive increase of the concentration of the iodinated contrast was associated with increased signal loss on MR and progressive increase of density values on CT. Temperature variations were associated with signal intensity changes on T2W and FIESTA images, but not on T1W images. CONCLUSION: At 1.5 T, a mixture of 50% iodinated contrast and 50% gadolinium contrast corresponded to an acceptable compromise for combined acquisition of MR and CT arthrography.

    [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Publishing Authors By Initials

    r detreilleR Detreille,b sauerB Sauer,jp zabelJP Zabel,t batchT Batch,x zhuX Zhu,a blumA Blum,r detreilleR Detreille,b sauerB Sauer,jp zabelJP Zabel,t batchT Batch,x zhuX Zhu,a blumA Blum,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Journal de radiologie

    VOLUME: 88

    Page Numbers: 863-9

    Journal Abbreviation:

    ISSN: 0221-0363

    DAY: 26

    MONTH: Jun

    YEAR: 2007

    [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Information

    Number of References:

    LANGUAGE: fre

    NlmUniqueID: 7906266

    [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography] Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for [Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography]

    AFFILIATION: Service d'Imagerie Guilloz, CHU Nancy, Av de lattre de Tassigny, 54000 Nancy.

    Country: France

    France Research PublicationFrance Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Radiol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Technical considerations for injection of a mixture of iodinated contrast material and Artirem for combined CT and MR arthrography Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News