  • T1 measurements incorporating flip angle calibration and correction in vivo. Abstract Text:

    jinghua wangJinghua Wang,maolin qiuMaolin Qiu,hyeonjin kimHyeonjin Kim,r todd constableR Todd Constable,

    In this work, we propose a variable FA method that combines in vivo flip angle (FA) calibration and correction with a short TR variable FA approach for a fast and accurate T(1) mapping. The precision T(1)s measured across a uniform milk phantom is estimated to be 2.65% using the conventional (slow) inversion recovery (IR) method and 28.5% for the variable FA method without FA correction, and 2.2% when FA correction is included. These results demonstrate that the sensitivity of the variable FA method to RF nonuniformities can be dramatically reduced when these nonuniformities are directly measured and corrected. The acquisition time for this approach decreases to 10 min from 85 min for the conventional IR method. In addition, we report that the averaged T(1)s measured from five normal subjects are 900 +/- 3 ms, 1337 +/- 8 ms and 2180 +/- 25 ms in white matter (WM), gray matter (GM) and cerebral spinal fluid (CSF) using the variable flip angle method with FA correction at 3 T, respectively. These results are consistent with previously reported values obtained with much longer acquisition times. The method reduces the total scan time for whole brain T(1) mapping, including FA measurement and calibration, to approximately 6 min. The novelty of this method lies in the in vivo calibration and the correction of the FAs, thereby allowing a rapid and accurate T(1) mapping at high field for many applications.

    T1 measurements incorporating flip angle calibration and correction in vivo. Publishing Authors By Initials

    j wangJ Wang,m qiuM Qiu,h kimH Kim,rt constableRT Constable,

    For similar equipment and supplies: phantoms, imaging research abstracts see: equipment and supplies: phantoms, imaging research

    PUBMED ID PMID:

    MEDLINE DATE:

    T1 measurements incorporating flip angle calibration and correction in vivo. Journal Published:

    PUBLICATION TYPE: Research Support, N.I.H., Extr

    Journal: Journal of magnetic resonance (San Diego, Calif. :

    VOLUME: 182

    Page Numbers: 283-92

    Journal Abbreviation: J. Magn. Reson.

    ISSN: 1090-7807

    DAY: 27

    MONTH: 07

    YEAR: 2006

    T1 measurements incorporating flip angle calibration and correction in vivo. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9707935

    T1 measurements incorporating flip angle calibration and correction in vivo. Keywords Mesh Terms:

    KEYWORDS: Phantoms, Imaging

    MESH TERMS: methods

    Chemical & Substance for Abstract: T1 measurements incorporating flip angle calibration and correction in vivo. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for T1 measurements incorporating flip angle calibration and correction in vivo.

    AFFILIATION: Department of Diagnostic Radiology, Yale University School Medical Center, The Anlyan Center, 330 Cedar Street, P.O. Box 208042, New Haven, CT 06520-8042, USA. Jinghua.wang@yale.edu

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NINDS

    GRANT: NS40497

    ACRONYM: NS

    MEDLINETA: J Magn Reson

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    T1 measurements incorporating flip angle calibration and correction in vivo Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News