Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

[Study on the surface roughness of three dental alloys soaked in artificial saliva]

[Study on the surface roughness of three dental alloys soaked in artificial saliva] Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • [Study on the surface roughness of three dental alloys soaked in artificial saliva] Abstract Text:

    jian-feng maJian-feng Ma,jin-song liuJin-song Liu,da-feng zhangDa-feng Zhang,si-qian wangSi-qian Wang,wei wangWei Wang,yong-lie chaoYong-lie Chao,

    PURPOSE: The aim of this study was to investigate the corrosion behavior of three metal materials for dental use (Co-Cr alloy, Ni-Cr alloy, titanium) by measurement of their surface roughness after soaked in artificial saliva with two different pH values. METHODS: Standard samples were casted respectively from 3 different alloys and grided into the same roughness .Then the samples were exposed to artificial saliva with two different pH values. After three months,the surface roughness of the samples was tested, and the microstructure of surfaces was studied by metalloscope. The data were analyzed with SPSS11.0 software package for one-way ANOVA and t test. RESULTS: There was significant difference in surface roughness of three alloys after exposed to artificial saliva with pH5.6. The surface roughness values of three alloys were listed as follows: Ni-Cr alloy>Co-Cr alloy >titanium(P<0.01). When exposed to artificial saliva with pH7.0, Ni-Cr alloy was found rougher than Co-Cr alloy and titanium(P<0.01), while there was no significant difference in roughness between Co-Cr alloy and titanium(P>0.05).Ni-Cr alloy and Co-Cr alloy soaked in artificial saliva with pH5.6 were found rougher than the same material in artificial saliva with pH7.0(P<0.01).The microstructure of the samples' surface verified the results. CONCLUSION: Titanium was stable not only in neutral environment but also in acid environment. The corrosion resistance of Co-Cr alloy and Ni-Cr alloy was superior in neutral environment than in acid environment. The corrosion resistance of the three alloys was: Titanium >Co-Cr alloy >Ni-Cr alloy.

    [Study on the surface roughness of three dental alloys soaked in artificial saliva] Publishing Authors By Initials

    jf maJF Ma,js liuJS Liu,df zhangDF Zhang,sq wangSQ Wang,w wangW Wang,yl chaoYL Chao,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    [Study on the surface roughness of three dental alloys soaked in artificial saliva] Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Shanghai kou qiang yi xue = Shanghai journal of st

    VOLUME: 16

    Page Numbers: 307-10

    Journal Abbreviation:

    ISSN: 1006-7248

    DAY: 30

    MONTH: Jun

    YEAR: 2007

    [Study on the surface roughness of three dental alloys soaked in artificial saliva] Information

    Number of References:

    LANGUAGE: chi

    NlmUniqueID: 101090220

    [Study on the surface roughness of three dental alloys soaked in artificial saliva] Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: [Study on the surface roughness of three dental alloys soaked in artificial saliva] Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for [Study on the surface roughness of three dental alloys soaked in artificial saliva]

    AFFILIATION: Department of Prosthetics, School and Hospital of Stomatology, Wenzhou Medical College, Wenzhou 325027, Zhejiang Province, China.

    Country: China

    China Research PublicationChina Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Shanghai Kou Qiang Yi Xue

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Study on the surface roughness of three dental alloys soaked in artificial saliva Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News