Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.

Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Abstract Text:

    giovanni m lasioGiovanni M Lasio,bruce r whitingBruce R Whiting,jeffrey f williamsonJeffrey F Williamson,

    Statistical image reconstruction (SR) algorithms have the potential to significantly reduce x-ray CT image artefacts because they use a more accurate model than conventional filtered backprojection and can incorporate effects such as noise, incomplete data and nonlinear detector response. Most SR algorithms assume that the CT detectors are photon-counting devices and generate Poisson-distributed signals. However, actual CT detectors integrate energy from the x-ray beam and exhibit compound Poisson-distributed signal statistics. This study presents the first assessment of the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram data model and the reconstruction algorithm. A 2D CT projection simulator was created to generate synthetic polyenergetic transmission data assuming (i) photon-counting with simple Poisson-distributed signals and (ii) energy-weighted detection with compound Poisson-distributed signals. An alternating minimization (AM) algorithm was used to reconstruct images from the data models (i) and (ii) for a typical abdominal scan protocol with incident particle fluence levels ranging from 10(5) to 1.6 x 10(6) photons/detector. The images reconstructed from data models (i) and (ii) were compared by visual inspection and image-quality figures of merit. The reconstructed image quality degraded significantly when the means were mismatched from the assumed model. However, if the signal means are appropriately modified, images from data models (i) and (ii) did not differ significantly even when SNR is very low. While data-mean mismatches characteristic of the difference between particle-fluence and energy-fluence transmission can cause significant streaking and cupping artefacts, the mismatch between the actual and assumed CT detector signal statistics did not significantly degrade image quality once systematic data means mismatches were corrected.

    Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Publishing Authors By Initials

    gm lasioGM Lasio,br whitingBR Whiting,jf williamsonJF Williamson,

    For similar equipment and supplies: transducers research abstracts see: equipment and supplies: transducers research

    PUBMED ID PMID:

    MEDLINE DATE:

    Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Journal Published:

    PUBLICATION TYPE: Research Support, N.I.H., Extr

    Journal: Physics in medicine and biology

    VOLUME: 52

    Page Numbers: 2247-66

    Journal Abbreviation:

    ISSN: 0031-9155

    DAY: 2

    MONTH: 04

    YEAR: 2007

    Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 401220

    Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Keywords Mesh Terms:

    KEYWORDS: Transducers

    MESH TERMS: methods

    Chemical & Substance for Abstract: Statistical reconstruction for x-ray computed tomography using energy-integrating detectors. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.

    AFFILIATION: Division of Medical Physics, Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA 23298, USA.

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY: United States NCI

    GRANT: R01 CA 75731

    ACRONYM: CA

    MEDLINETA: Phys Med Biol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Statistical reconstruction for x-ray computed tomography using energy-integrating detectors Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News