Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope.

Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Abstract Text:

    AIM: To evaluate the reproducibility of the background fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. METHODS: 10 normal volunteers and 10 patients with retinal disease were included in the study. One eye per subject was chosen randomly. Five images of the same eye of each individual were obtained, after pupillary dilatation, by two investigators using a confocal scanning laser ophthalmoscope. Background fundus autofluorescence was measured at 7 degrees temporal to the fovea in normal volunteers and between 7 and 15 degrees temporal to the fovea in patients. Within session reproducibility of the measurements obtained by each investigator and interobserver reproducibility were evaluated. RESULTS: For investigator 1 the median values of fundus autofluorescence obtained were 31.9 units for normal volunteers and 27.3 units for patients. The median largest differences in readings in normal volunteers was 5.7 units (range 1.4-13.5 units) and in patients 4.2 units (1.5-15.1 units). For investigator 2 the median values of fundus autofluorescence obtained were 28.9 units for normal volunteers and 27.4 units for patients. The median largest difference in readings in normal volunteers was 3.6 units (2.7-11.7 units), and in patients 4.1 units (1.5-9.3 units). The median interobserver difference in readings in normal volunteers was 3.3 units and for patients 6.6 units. The median greatest interobserver difference in measurements obtained for normal volunteers was 8.8 units (8.4-23.0 units) and for patients 11.1 units (7.1-40.8 units). CONCLUSION: Within session reproducibility of the measurements of background fundus autofluorescence was satisfactory. Although interobserver reproducibility was moderate, the variability of the measurements of fundus autofluorescence between observers appears to be small when compared with variation in fundus autofluorescence with age and disease.

    Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Publishing Authors By Initials

    For similar eye diseases: retinal diseases research abstracts see: eye diseases: retinal diseases research

    PUBMED ID PMID:

    MEDLINE DATE:

    Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: The British journal of ophthalmology

    VOLUME: 83

    Page Numbers: 276-9

    Journal Abbreviation: Br J Ophthalmol

    ISSN: 0007-1161

    DAY: 28

    MONTH: Mar

    YEAR: 1999

    Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 421041

    Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Keywords Mesh Terms:

    KEYWORDS: Retinal Diseases

    MESH TERMS: metabolism

    Chemical & Substance for Abstract: Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Information

    Substance Name: Lipofuscin

    Registry Number: 0

    Grant and Affiliation Information for Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope.

    AFFILIATION: Institute of Ophthalmology, London.

    Country: ENGLAND

    ENGLAND Research PublicationENGLAND Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Br J Ophthalmol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News