Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis.

Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Abstract Text:

    h e ashH E Ash,a unsworthA Unsworth,

    The bones from 83 proximal interphalangeal joints (PIPJs) were dissected in order to determine the shape and size of the articular surfaces. The bones were modelled in acrylic dental bone cement and the original bones and replicas were then sectioned and shadowgraphed. Dimensions were taken from these shadowgraphs to be used in the design of a surface replacement prosthesis for the PIPJ. It was found that the bi-condylar heads of the proximal and middle phalanges were circular in the sagittal plane as was the base of the middle phalanx. However, the radius of curvature of the middle phalangeal base was greater than that of the proximal phalangeal head indicating that the PIPJ is not a conforming joint. The alignment of the radial and ulnar condyles of the proximal phalangeal bones was investigated and it was found that the index and middle finger bones tended to have a more prominent ulnar condyle while the ring and little finger bones tended to have a more prominent radial condyle. This was due to a slight difference in diameters of the two condyles. The proximal phalangeal bone lengths L ranged from 29-52 mm, maximum head widths W from 8.5-15.5 mm and maximum diameters D of the best-fit circles to the sagittal profile of the bone head from 6-11 mm. The middle phalangeal bone lengths ranged from 16-35 mm, maximum head widths from 8.5-12 mm and maximum diameters from 5-7.5 mm. The relationships and ratios between these dimensions for the proximal and middle phalanges have been calculated.

    Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Publishing Authors By Initials

    he ashHE Ash,a unsworthA Unsworth,

    For similar reproductive and urinary physiology: reproduction: sex characteristics research abstracts see: reproductive and urinary physiology: reproduction: sex characteristics research

    PUBMED ID PMID:

    MEDLINE DATE:

    Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Proceedings of the Institution of Mechanical Engin

    VOLUME: 210

    Page Numbers: 95-108

    Journal Abbreviation:

    ISSN: 0954-4119

    DAY: 21

    MONTH: 02

    YEAR: 1996

    Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8908934

    Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Keywords Mesh Terms:

    KEYWORDS: Sex Characteristics

    MESH TERMS: physiology

    Chemical & Substance for Abstract: Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis.

    AFFILIATION: School of Engineering, University of Durham.

    Country: ENGLAND

    ENGLAND Research PublicationENGLAND Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Proc Inst Mech Eng [H]

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Proximal interphalangeal joint dimensions for the design of a surface replacement prosthesis Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News