Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT.

Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Abstract Text:

    h kondoH Kondo,m kanematsuM Kanematsu,h hoshiH Hoshi,t murakamiT Murakami,t kimT Kim,m horiM Hori,m matsuoM Matsuo,h nakamuraH Nakamura,

    OBJECTIVE: We compared radiologists' performance on combined unenhanced, gadolinium-enhanced, and ferumoxides-enhanced MR imaging with their performance on helical CT during arterial portography (CTAP) and biphasic CT during hepatic arteriography (CTHA) for the preoperative detection of malignant hepatic tumors. SUBJECTS AND METHODS: MR images and CT scans obtained in 33 patients were retrospectively analyzed. Images of the liver were reviewed on a segment-by-segment basis; a total of 261 segments with 39 hepatocellular carcinomas and 21 metastases were independently reviewed by three radiologists who were invited from outside institutions. Unenhanced and gadolinium-enhanced MR images were reviewed first, then ferumoxides-enhanced MR images were added for combined review. CTAP images and biphasic CTHA images were reviewed together. RESULTS: Sensitivity for the detection of hepatic tumors was analogous for combined unenhanced, gadolinium-enhanced, and ferumoxides-enhanced MR images (86%) and for combined CTAP images and biphasic CTHA images (87%). Specificity was higher with MR images (95%, p < 0.01) than with CT images (91%). Radiologists' performances were improved (Az = 0.962, p = 0.0502) by combining ferumoxides-enhanced MR images with unenhanced and gadolinium-enhanced MR images (Az = 0.950), and were analogous for combined unenhanced, gadolinium-enhanced, and ferumoxides-enhanced MR images and for combined CTAP images and biphasic CTHA images (Az = 0.959). CONCLUSION: Radiologists' performances on combined unenhanced, gadolinium-enhanced, and ferumoxides-enhanced MR imaging compared with their performances on combined helical CTAP and biphasic CTHA are analogous for the preoperative detection of malignant hepatic tumors. Such a dedicated combination of MR imaging may obviate the need for more invasive angiographically assisted helical CT for the preoperative detection of malignant hepatic tumors.

    Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Publishing Authors By Initials

    h kondoH Kondo,m kanematsuM Kanematsu,h hoshiH Hoshi,t murakamiT Murakami,t kimT Kim,m horiM Hori,m matsuoM Matsuo,h nakamuraH Nakamura,

    For similar tomography, x-ray computed research abstracts see: tomography, x-ray computed research

    PUBMED ID PMID:

    MEDLINE DATE:

    Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJR. American journal of roentgenology

    VOLUME: 174

    Page Numbers: 947-54

    Journal Abbreviation:

    ISSN: 0361-803X

    DAY: 15

    MONTH: Apr

    YEAR: 2000

    Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7708173

    Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Keywords Mesh Terms:

    KEYWORDS: Tomography, X-Ray Computed

    MESH TERMS: diagnostic use

    Chemical & Substance for Abstract: Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Information

    Substance Name: Gadolinium

    Registry Number: 7440-54-2

    Grant and Affiliation Information for Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT.

    AFFILIATION: Department of Radiology, Gifu University School of Medicine, Japan.

    Country: UNITED STATES

    UNITED STATES Research PublicationUNITED STATES Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJR Am J Roentgenol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News