Preliminary clinical application of contrast-enhanced MR portography.

Preliminary clinical application of contrast-enhanced MR portography. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Preliminary clinical application of contrast-enhanced MR portography. Abstract Text:

    l yangL Yang,x kongX Kong,d liuD Liu,x xiaoX Xiao,g fengG Feng,

    The clinical application of contrast enhanced (CE) MR was evaluated. A total of 66 CE MR portograms were obtained by performing fast imaging with steady procession (FISP) technique on a 1.5-T Siemens magnetom vision. A maximum intensity projection algorithm was also employed to include all vessels in a single image. The patency of portal venous system, the presence and extent of varices were also evaluated. The results showed that all images had diagnostic quality. Main portal vein (MPV) and its 4th-6th level intrahepatic branches were visualized in 10 normal persons serving as control. The diameter of MPV, splenic vein and superior mesenteric vein was 1.02 +/- 0.21, 0.8 +/- 0.15, 0.8 +/- 0.26 cm respectively, which were significantly lower than that in portal hypertension patients (1.38 +/- 0.27, 1.26 +/- 0.18, 1.24 +/- 0.18 cm, respectively). In 23 preoperative cases of portal hypertension, dilated portal vein and tortuous enlarged splenic vein were found in 23 cases; esophageal and coronary varices in 12 and 19 cases, respectively. In 7 postoperative re-examined cases with portal hypertension, the flow velocity and flow of MPV were decreased in all cases and esophageal varices could still be observed in 3 cases. New vessels appeared in the great curvature of stomach in 2 cases. In 20 cases of liver carcinoma, occlusion of MPV or its intrahepatic branches were showed in 14, compression and dislocation of intrahepatic portal vein were found in 6. In other 6 cases, 2 were splenic venous thrombosis and 4 were tumors in the intestine or retro-peritoneum. It is concluded that three-dimensional CE MR portography is an accurate technique for evaluating the portal venous system. It is a reliable and noninvasive technique that can provide important information for the evaluation of patients' condition before TIPSS and liver transplantation.

    Preliminary clinical application of contrast-enhanced MR portography. Publishing Authors By Initials

    l yangL Yang,x kongX Kong,d liuD Liu,x xiaoX Xiao,g fengG Feng,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Preliminary clinical application of contrast-enhanced MR portography. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Journal of Tongji Medical University = Tong ji yi

    VOLUME: 19

    Page Numbers: 323-7

    Journal Abbreviation: J. Tongji Med. Univ.

    ISSN: 0257-716X

    DAY: 26

    MONTH: 08

    YEAR: 1999

    Preliminary clinical application of contrast-enhanced MR portography. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8605495

    Preliminary clinical application of contrast-enhanced MR portography. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Preliminary clinical application of contrast-enhanced MR portography. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Preliminary clinical application of contrast-enhanced MR portography.

    AFFILIATION: Department of Radiology, Xiehe Hospital, Tongji Medical University, Wuhan 430022.

    Country: China

    China Research PublicationChina Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Tongji Med Univ

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Preliminary clinical application of contrast-enhanced MR portography Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News