Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil.

Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Abstract Text:

    k sakaiK Sakai,y ugawaY Ugawa,y teraoY Terao,r hanajimaR Hanajima,t furubayashiT Furubayashi,i kanazawaI Kanazawa,

    Transcranial magnetic stimulation (TMS) over the human primary motor cortex (MI) evokes motor responses in the contralateral limb muscles. The latencies and amplitudes of those responses depend on the direction of induced current in the brain by the stimuli (Mills et al. 1992, Werhahn et al. 1994). This observation suggests that different neural elements might be activated by the differently directed induced currents. Using a figure-of-eight-shaped coil, which induces current with a certain direction, we analyzed the effect of direction of stimulating current on the latencies of responses to TMS in normal subjects. The latencies were measured from surface electromyographic responses of the first dorsal interosseous muscles and the peaks in the peristimulus time histograms (PSTHs) of single motor units from the same muscles. The coil was placed over the MI, with eight different directions each separated by 45 degrees. Stimulus intensity was adjusted just above the motor threshold while subjects made a weak tonic voluntary contraction, so that we can analyse the most readily elicited descending volley in the pyramidal tracts. In most subjects, TMS with medially and anteriorly directed current in the brain produced responses or a peak that occurred some 1.5 ms later than those to anodal electrical stimulation. In contrast, TMS with laterally and posteriorly directed current produced responses or a peak that occurred about 4.5 ms later. There was a single peak in most of PSTHs under the above stimulation condition, whereas there were occasionally two peaks under the transitional current directions between the above two groups. These results suggest that TMS with medially and anteriorly directed current in the brain readily elicits I1 waves, whereas that with laterally and posteriorly directed current preferentially elicits I3 waves. Functional magnetic resonance imaging studies indicated that this direction was related to the course of the central sulcus. TMS with induced current flowing forward relative to the central sulcus preferentially elicited I1 waves and that flowing backward elicited I3 waves. Our finding of the dependence of preferentially activated I waves on the current direction in the brain suggests that different sets of cortical neurons are responsible for different I waves, and are contrarily oriented. The present method using a figure-of-eight-shaped coil must enable us to study physiological characteristics of each I wave separately and, possibly, analyse different neural elements in MI, since it activates a certain I wave selectively without D waves or other I waves.

    Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Publishing Authors By Initials

    k sakaiK Sakai,y ugawaY Ugawa,y teraoY Terao,r hanajimaR Hanajima,t furubayashiT Furubayashi,i kanazawaI Kanazawa,

    For similar diagnosis: diagnostic techniques and procedures: diagnostic techniques, neurological: transcranial magnetic stimulation research abstracts see: diagnosis: diagnostic techniques and procedures: diagnostic techniques, neurological: transcranial magnetic stimulation research

    PUBMED ID PMID:

    MEDLINE DATE:

    Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: Experimental brain research. Experimentelle Hirnfo

    VOLUME: 113

    Page Numbers: 24-32

    Journal Abbreviation:

    ISSN: 0014-4819

    DAY: 15

    MONTH: Jan

    YEAR: 1997

    Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 43312

    Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Keywords Mesh Terms:

    KEYWORDS: Transcranial Magnetic Stimulation

    MESH TERMS: physiology

    Chemical & Substance for Abstract: Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil.

    AFFILIATION: Department of Neurology, School of Medicine, University of Tokyo, Japan.

    Country: GERMANY

    GERMANY Research PublicationGERMANY Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Exp Brain Res

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News