Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases.

Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Abstract Text:

    BACKGROUND AND AIM OF THE STUDY: The study aim was to determine the three-dimensional motion of the semilunar attachment of leaflets (annulus) and the aortic root in annuloaortic ectasia with aortic insufficiency (AI). METHODS: Five patients (four males, one female) underwent preoperative and postoperative 64-row, multidetector computed tomography (MDCT) and aortic root remodeling with aortic annuloplasty. The control group comprised 25 subjects who underwent MDCT scanning for reasons other than cardiac evaluation. The aortic annulus was measured at systole and diastole, and then divided into the right coronary cusp (RCC), left coronary cusp (LCC) and non-coronary cusp (NCC). The lengths of the aortic annulus, sinus of Valsalva and sinotubular junction (STJ) were also measured at systole and diastole on longitudinal views. RESULTS: The preoperative and postoperative systolic and diastolic lengths of the RCC, LCC and NCC did not differ significantly, but all were significantly larger than those in control subjects. The preoperative diameters of the aortic annulus and STJ were significantly larger at systole than at diastole. However, the control findings indicated that only the STJ diameter was larger at systole than at diastole. CONCLUSION: The aortic annulus length did not change perioperatively at systole and diastole. Aortic root remodeling with aortic annuloplasty corrects the preoperative motion of the aortic annulus and STJ, which might be the cause of AI, although STJ distensibility was restricted.

    Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Publishing Authors By Initials

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: The Journal of heart valve disease

    VOLUME: 17

    Page Numbers: 366-70

    Journal Abbreviation: J. Heart Valve Dis.

    ISSN: 0966-8519

    DAY: 28

    MONTH: Jul

    YEAR: 2008

    Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9312096

    Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases.

    AFFILIATION: Department of Cardiovascular Surgery, Memorial Heart Center, Iwate Medical University, Morioka City, Iwate, Japan. t-kazui@pf6.so-net.ne.jp

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Heart Valve Dis

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Perioperative dynamic morphological changes of the aortic annulus during aortic root remodeling with aortic annuloplasty at systolic and diastolic phases Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News