Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Abstract Text:

    beate timmermannBeate Timmermann,antony jonathan lomaxAntony Jonathan Lomax,luisa nobileLuisa Nobile,michael andreas grotzerMichael Andreas Grotzer,markus weissMarkus Weiss,rolf-dieter kortmannRolf-Dieter Kortmann,alessandra bolsiAlessandra Bolsi,gudrun goiteinGudrun Goitein,

    BACKGROUND AND PURPOSE: Conventional craniospinal irradiation (CSI) is a complex procedure carrying a high risk of adverse side effects. Still, it is indispensable for cure in a number of pediatric brain tumors. In this study, the feasibility and the potential advantage of spot-scanning proton therapy for CSI are investigated. MATERIAL AND METHODS: A boy (5.5 years of age) with a recurrent medulloblastoma received CSI with a single posterior field using the spot-scanning system at Paul Scherrer Institute. Dose distribution to the targets and the organs at risk, treatment time, reproducibility of patient positioning, toxicity (according to EORTC/RTOG score), and treatment outcome were evaluated. RESULTS: The plan achieved a homogeneous coverage of the target volume, even using a single field. The doses to the organs ventral to the target were minimized. During treatment, grade 1 skin reaction and grade 2 central nervous system toxicity were observed. After 2 months, the boy presented with a transitory fatigue. After 24 months, he is alive and free of disease. Growth hormones and thyroid hormones are reduced. CONCLUSION: These results, based on a single patient, suggest that spot-scanning proton therapy for craniospinal treatment is feasible and safe. By applying a single dorsal field, difficulties of multiple-field patching can be avoided and the ventral dose spread can be minimized.

    Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Publishing Authors By Initials

    b timmermannB Timmermann,aj lomaxAJ Lomax,l nobileL Nobile,ma grotzerMA Grotzer,m weissM Weiss,rd kortmannRD Kortmann,a bolsiA Bolsi,g goiteinG Goitein,

    For similar diagnosis: prognosis: treatment outcome research abstracts see: diagnosis: prognosis: treatment outcome research

    PUBMED ID PMID:

    MEDLINE DATE:

    Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Strahlentherapie und Onkologie : Organ der Deutsch

    VOLUME: 183

    Page Numbers: 685-8

    Journal Abbreviation:

    ISSN: 0179-7158

    DAY: 11

    MONTH: Dec

    YEAR: 2007

    Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8603469

    Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Keywords Mesh Terms:

    KEYWORDS: Treatment Outcome

    MESH TERMS: instrumentation

    Chemical & Substance for Abstract: Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution. Information

    Substance Name: Protons

    Registry Number: 0

    Grant and Affiliation Information for Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution.

    AFFILIATION: Center for Proton Radiation Therapy, Paul Scherrer Institute, Villigen, Switzerland. beate.timmermann@psi.ch

    Country: Germany

    Germany Research PublicationGermany Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Strahlenther Onkol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Novel technique of craniospinal axis proton therapy with the spot-scanning system: avoidance of patching multiple fields and optimized ventral dose distribution Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News