Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

MR imaging-related heating of deep brain stimulation electrodes: in vitro study.

MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Abstract Text:

    daniel a finelliDaniel A Finelli,ali r rezaiAli R Rezai,paul m ruggieriPaul M Ruggieri,jean a tkachJean A Tkach,john a nyenhuisJohn A Nyenhuis,greg hrdlickaGreg Hrdlicka,ashwini sharanAshwini Sharan,jorge gonzalez-martinezJorge Gonzalez-Martinez,paul h stypulkowskiPaul H Stypulkowski,frank g shellockFrank G Shellock,

    BACKGROUND AND PURPOSE: Recent work has shown a potential for excessive heating of deep brain stimulation electrodes during MR imaging. This in vitro study investigates the relationship between electrode heating and the specific absorption rate (SAR) of several MR images. METHODS: In vitro testing was performed by using a 1.5-T MR imaging system and a head transmit-receive coil, with bilateral deep brain stimulation systems positioned in a gel saline-filled phantom, and temperature monitoring with a fluoroptic thermometry system. Standardized fast spin-echo sequences were performed over a range of high, medium, and low SAR values. Several additional, clinically important MR imaging techniques, including 3D magnetization prepared rapid acquisition gradient-echo imaging, echo-planar imaging, quantitative magnetization transfer imaging, and magnetization transfer-suppressed MR angiography, were also tested by using typical parameters. RESULTS: A significant, highly linear relationship between SAR and electrode heating was found, with the temperature elevation being approximately 0.9 times the local SAR value. Minor temperature elevations, <1 degrees C, were found with the fast spin-echo, magnetization prepared rapid acquisition gradient-echo, and echo-planar clinical imaging sequences. The high dB/dt echo-planar imaging sequence had no significant heating independent of SAR considerations. Sequences with magnetization transfer pulses produced temperature elevations in the 1.0 to 2.0 degrees C range, which was less than theoretically predicted for the relatively high SAR values. CONCLUSION: A potential exists for excessive MR imaging-related heating in patients with deep brain stimulation electrodes; however, the temperature increases are linearly related to SAR values. Clinical imaging sequences that are associated with tolerable temperature elevations in the

    MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Publishing Authors By Initials

    da finelliDA Finelli,ar rezaiAR Rezai,pm ruggieriPM Ruggieri,ja tkachJA Tkach,ja nyenhuisJA Nyenhuis,g hrdlickaG Hrdlicka,a sharanA Sharan,j gonzalez-martinezJ Gonzalez-Martinez,ph stypulkowskiPH Stypulkowski,fg shellockFG Shellock,

    For similar predictive value of tests research abstracts see: predictive value of tests research

    PUBMED ID PMID:

    MEDLINE DATE:

    MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJNR. American journal of neuroradiology

    VOLUME: 23

    Page Numbers: 1795-802

    Journal Abbreviation:

    ISSN: 0195-6108

    DAY: 14

    MONTH: 02

    YEAR: 2008

    MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8003708

    MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Keywords Mesh Terms:

    KEYWORDS: Predictive Value of Tests

    MESH TERMS: instrumentation

    Chemical & Substance for Abstract: MR imaging-related heating of deep brain stimulation electrodes: in vitro study. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for MR imaging-related heating of deep brain stimulation electrodes: in vitro study.

    AFFILIATION: Division of Radiology, Section of Stereotactic and Functional Neurosurgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJNR Am J Neuroradiol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    MR imaging-related heating of deep brain stimulation electrodes: in vitro study Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News