Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography.

Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Abstract Text:

    kenji suzukiKenji Suzuki,hiroyuki yoshidaHiroyuki Yoshida,janne Janne ,samuel g armatoSamuel G Armato,abraham h dachmanAbraham H Dachman,

    One of the major challenges in computer-aided detection (CAD) of polyps in CT colonography (CTC) is the reduction of false-positive detections (FPs) without a concomitant reduction in sensitivity. A large number of FPs is likely to confound the radiologist's task of image interpretation, lower the radiologist's efficiency, and cause radiologists to lose their confidence in CAD as a useful tool. Major sources of FPs generated by CAD schemes include haustral folds, residual stool, rectal tubes, the ileocecal valve, and extra-colonic structures such as the small bowel and stomach. Our purpose in this study was to develop a method for the removal of various types of FPs in CAD of polyps while maintaining a high sensitivity. To achieve this, we developed a "mixture of expert" three-dimensional (3D) massive-training artificial neural networks (MTANNs) consisting of four 3D MTANNs that were designed to differentiate between polyps and four categories of FPs: (1) rectal tubes, (2) stool with bubbles, (3) colonic walls with haustral folds, and (4) solid stool. Each expert 3D MTANN was trained with examples from a specific non-polyp category along with typical polyps. The four expert 3D MTANNs were combined with a mixing artificial neural network (ANN) such that different types of FPs could be removed. Our database consisted of 146 CTC datasets obtained from 73 patients whose colons were prepared by standard pre-colonoscopy cleansing. Each patient was scanned in both supine and prone positions. Radiologists established the locations of polyps through the use of optical-colonoscopy reports. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. The CTC cases were subjected to our previously reported CAD method consisting of centerline-based extraction of the colon, shape-based detection of polyp candidates, and a Bayesian-ANN-based classification of polyps. The original CAD method yielded 96.4% (27/28) by-polyp sensitivity with an average of 3.1 (224/73) FPs per patient. The mixture of expert 3D MTANNs removed 63% (142/224) of the FPs without the loss of any true positive; thus, the FP rate of our CAD scheme was improved to 1.1 (82/73) FPs per patient while the original sensitivity was maintained. By use of the mixture of expert 3D MTANNs, the specificity of a CAD scheme for detection of polyps in CTC was substantially improved while a high sensitivity was maintained.

    Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Publishing Authors By Initials

    k suzukiK Suzuki,h yoshidaH Yoshida,j J ,sg armatoSG Armato,ah dachmanAH Dachman,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: Medical physics

    VOLUME: 35

    Page Numbers: 694-703

    Journal Abbreviation:

    ISSN: 0094-2405

    DAY: 3

    MONTH: Feb

    YEAR: 2008

    Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 425746

    Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography.

    AFFILIATION: Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, Chicago, Illinois 60637, USA. suzuki@uchicago.edu

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Med Phys

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Mixture of expert 3D massive-training ANNs for reduction of multiple types of false positives in CAD for detection of polyps in CT colonography Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News