Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker.

Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Abstract Text:

    tasneem z naqviTasneem Z Naqvi,william barnettWilliam Barnett,

    BACKGROUND: Atrial flutter is a common cause of exacerbation of congestive heart failure (CHF). Typically, during atrial tachycardia, pacemakers, both dual and biventricular, are programmed to ignore atrial tracking. Virtually all current pacemakers and defibrillators use a programmable mode switch algorithm to switch between atrial tracking modes (DDD, DDDR) to nontracking modes (DDIR, DDI, VVI) during episodes of atrial tachycardia. METHODS: In this report, we describe a novel method of atrioventricular (AV) pacemaker programming in four patients with atrial flutter and CHF who remained symptomatic postbiventricular pacemaker implantation. All patients had chronic atrial flutter upon interrogation; adjustment of AV delay and postventricular atrial refractory period (PVARP) was performed to enable sensing of every second to fourth atrial flutter beat by the atrial lead. Mode switch was turned "OFF" in all points, and lower and upper rate limits were set to 50 and 100 bpm. Once sequential early and late diastolic filling was seen on mitral inflow pulsed-wave (PW) Doppler, further adjustment of AV delay and PVARP was performed until the highest and broadest atrial velocity occurred on mitral inflow PW Doppler. RESULTS: All patients developed improvement in aortic ejection duration and peak ejection velocity during AV optimization. Repeat ECG in these patients at 8 months, 7 days, 2 days, and 2 months postoptimization showed no change in P and QRS relationship. All patients developed improvement in CHF symptoms postbiv pacemaker optimization. CONCLUSION: In symptomatic patients with CHF and stable atrial flutter who have a biventricular pacemaker, atrial mechanical contribution to cardiac output can be achieved by adjusting PVARP and AV delay during echo-guided pacemaker programming.

    Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Publishing Authors By Initials

    tz naqviTZ Naqvi,w barnettW Barnett,

    For similar equipment and supplies: surgical equipment: artificial organs: pacemaker, artificial research abstracts see: equipment and supplies: surgical equipment: artificial organs: pacemaker, artificial research

    PUBMED ID PMID:

    MEDLINE DATE:

    Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Pacing and clinical electrophysiology : PACE

    VOLUME: 30

    Page Numbers: 948-56

    Journal Abbreviation:

    ISSN: 0147-8389

    DAY: 20

    MONTH: Aug

    YEAR: 2007

    Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7803944

    Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Keywords Mesh Terms:

    KEYWORDS: Pacemaker, Artificial

    MESH TERMS: physiopathology

    Chemical & Substance for Abstract: Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker.

    AFFILIATION: Cardiac Non-Invasive Laboratory, Division of Cardiology, Department of Medicine, Cedars-Sinai Medical Center, 8700 Beverly Boulevard, Los Angeles, CA 90048, USA. tasneem.naqvi@cshs.org

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Pacing Clin Electrophysiol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News