Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass.

Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Abstract Text:

    michael t ganterMichael T Ganter,antoinette monnAntoinette Monn,reza tavakoliReza Tavakoli,richard klaghoferRichard Klaghofer,andreas zollingerAndreas Zollinger,christoph k hoferChristoph K Hofer,

    OBJECTIVES: In vivo data for the kaolin-based ACT test from the Sonoclot Analyzer (SkACT, Sienco Inc, Arvada, CO) are lacking. The aim of this study was to compare SkACT with an established kaolin-based ACT from Hemochron (HkACT) and anti-Xa activity in patients undergoing cardiopulmonary bypass (CPB). DESIGN: Prospective observational study. SETTING: Community hospital. PARTICIPANTS: Fifty patients scheduled for elective cardiac surgery. INTERVENTIONS: Blood samples were taken before CPB at baseline (T0) and after heparinization (T1 and T2), on CPB after administration of aprotinin (5, 15, 30, 60 minutes; T3-T6), and at the end after protamine infusion (T7). MEASUREMENTS AND MAIN RESULTS: A total of 375 blood samples were analyzed. ACT measurements were comparable for SkACT and HkACT at each measurement time point. Overall bias +/- standard deviation between SkACT and HkACT was -19 +/- 75 seconds (-2.4% +/- 11.7%). Mean bias between SkACT and HkACT at each time point ranged from -35 to 3 seconds (-4.5% to 2.6%) and showed no statistical significance over time. Heparin sensitivity of SkACT and HkACT, defined as (ACT(Tx)-ACT(T0))/(anti-Xa(Tx)-anti-Xa(T0)), significantly increased for measurements during CPB (p < 0.001) but without significant difference between the 2 methods. Test variability was comparable for both ACT measurement techniques. Overall test variability was 7.5% +/- 7.4% for SkACT and 7.8% +/- 11% for HkACT. CONCLUSIONS: Accuracy and performance of SkACT and HkACT were comparable for heparin monitoring in patients undergoing CPB for elective cardiac surgery. However, both tests were affected significantly after initiating CPB and aprotinin infusion.

    Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Publishing Authors By Initials

    mt ganterMT Ganter,a monnA Monn,r tavakoliR Tavakoli,r klaghoferR Klaghofer,a zollingerA Zollinger,ck hoferCK Hofer,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Journal of cardiothoracic and vascular anesthesia

    VOLUME: 21

    Page Numbers: 524-8

    Journal Abbreviation: J. Cardiothorac. Vasc. Anesth.

    ISSN: 1053-0770

    DAY: 9

    MONTH: 03

    YEAR: 2007

    Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9110208

    Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass.

    AFFILIATION: Department of Anesthesia and Perioperative Care, University of California San Francisco, San Francisco, CA 94110, USA. mt.ganter@gmail.com

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Cardiothorac Vasc Anesth

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiopulmonary bypass Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!