Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT.

Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Abstract Text:

    bing fengBing Feng,jeffrey a fesslerJeffrey A Fessler,michael a kingMichael A King,

    In order to reconstruct attenuation maps with improved spatial resolution and quantitative accuracy, we developed an approximate method of incorporating system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission reconstruction. Our method approximately models the blur caused by the finite intrinsic detector resolution, the nonideal source collimation and detector collimation. We derived the formulation using the optimization transfer principle as in the derivation of the OSTR algorithm. The formulation includes one forward-blur step and one back-blur step, which do not severely slow down reconstruction. The formulation could be applicable to various transmission geometries, such as point-source, line-source, and sheet-source systems. Through computer simulations of the MCAT phantom and transmission measurements of the air-filled Data Spectrum Deluxe single photo emission computed tomography (SPECT) Phantom on a system which employed a cone-beam geometry and a system which employed a scanning-line-source geometry, we showed that incorporation of RC increased spatial resolution and improved the quantitative accuracy of reconstruction. In simulation studies, attenuation maps reconstructed with RC correction improved the quantitative accuracy of emission reconstruction.

    Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Publishing Authors By Initials

    b fengB Feng,ja fesslerJA Fessler,ma kingMA King,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Journal Published:

    PUBLICATION TYPE: Research Support, N.I.H., Extr

    Journal: IEEE transactions on medical imaging

    VOLUME: 25

    Page Numbers: 941-9

    Journal Abbreviation:

    ISSN: 0278-0062

    DAY: 3

    MONTH: Jul

    YEAR: 2006

    Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8310780

    Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Keywords Mesh Terms:

    KEYWORDS: Tomography, Emission-Computed, Single-Ph

    MESH TERMS: methods

    Chemical & Substance for Abstract: Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT.

    AFFILIATION: Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655, USA. bing.feng@umassmed.edu

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NHLBI

    GRANT: HL50349

    ACRONYM: HL

    MEDLINETA: IEEE Trans Med Imaging

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Incorporation of system resolution compensation RC in the ordered-subset transmission OSTR algorithm for transmission imaging in SPECT Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News