In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique.

In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Abstract Text:

    y yamashitaY Yamashita,y abeY Abe,y tangY Tang,j urataJ Urata,s sumiS Sumi,m takahashiM Takahashi,

    OBJECTIVE: This study was undertaken to compare the in vitro and clinical value of two-dimensional multislice breath-hold MR cholangiopancreatography (MRCP) with a single-shot projection technique using a half-Fourier acquisition single-shot turbo spin-echo sequence. SUBJECTS AND METHODS: We examined 108 patients with pancreaticobiliary diseases, using breath-hold MRCP and a half-Fourier acquisition single-shot turbo spin-echo sequence on a 1.5-T MR unit with a body phased-array coil. Two data acquisition techniques were employed: multislice acquisition postprocessed by maximum intensity projection (MIP) (multislice technique) and single-shot projection with a thick slice (projection technique). In the multislice technique, nine contiguous slices were obtained with a thickness of 5 mm (acquisition time. 18 sec). In the projection technique, a single slice was obtained with a thickness of 30, 50, or 70 mm (acquisition time. 2 sec). Contrast-to-noise ratio (CNR) between the common bile duct and the liver as well as detectability of normal structures and diseases were compared for these two acquisition techniques. In the multislice technique, source images were also evaluated. ERCP or percutaneous transhepatic cholangiography images were used as the gold standard. RESULTS: Most of the pancreatic duct and common bile duct was revealed on 54% and 100% of the projection images, respectively, and on 35% and 98% of the MIP images, respectively, CNR was significantly higher with the multislice technique than with the projection technique (p < .01). With the projection technique, CNR decreased as slice thickness increased. Dilatation and occlusion of the pancreaticobiliary tree were equally well revealed by the two imaging techniques. However, abnormalities in the periampullary region and anomalies in the pancreaticobiliary tree were more clearly seen on projection images than on MIP images (p < .05). Stones in the common bile duct, gallbladder, or intrahepatic bile duct were best seen on source images acquired by the multislice technique (83% sensitivity). CONCLUSION: Because of the absence of misregistration and the speed of image acquisition, breath-hold single-shot MRCP using the projection technique with a slice thickness of 30 or 50 mm consistently revealed the pancreaticobiliary tree and periampullary region with an acceptable CNR. Stones in the bile duct were best seen on the source images acquired by the MIP technique.

    In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Publishing Authors By Initials

    y yamashitaY Yamashita,y abeY Abe,y tangY Tang,j urataJ Urata,s sumiS Sumi,m takahashiM Takahashi,

    For similar investigative techniques: epidemiologic methods: statistics as topic: sensitivity and specificity research abstracts see: investigative techniques: epidemiologic methods: statistics as topic: sensitivity and specificity research

    PUBMED ID PMID:

    MEDLINE DATE:

    In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJR. American journal of roentgenology

    VOLUME: 168

    Page Numbers: 1449-54

    Journal Abbreviation:

    ISSN: 0361-803X

    DAY: 15

    MONTH: Jun

    YEAR: 1997

    In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7708173

    In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Keywords Mesh Terms:

    KEYWORDS: Sensitivity and Specificity

    MESH TERMS: radiography

    Chemical & Substance for Abstract: In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique.

    AFFILIATION: Department of Radiology, Kumamoto University School of Medicine, Japan.

    Country: UNITED STATES

    UNITED STATES Research PublicationUNITED STATES Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJR Am J Roentgenol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News