Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation.

High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Abstract Text:

    emerson l gasparettoEmerson L Gasparetto,dante l escuissatoDante L Escuissato,edson marchioriEdson Marchiori,sérgio onoSérgio Ono,rodney l frare e silvaRodney L Frare e Silva,nestor l müllerNestor L Müller,

    OBJECTIVE: The aim of this study was to describe the high-resolution CT findings of respiratory syncytial virus pneumonia in 20 patients who had undergone allogeneic bone marrow transplantation. MATERIALS AND METHODS: The study included 20 consecutive patients who developed respiratory syncytial virus pneumonia after bone marrow transplantation and who had high-resolution CT of the chest performed within 24 hr after the onset of symptoms. The CT scans were reviewed by two chest radiologists who assessed the pattern and distribution of findings. RESULTS: Bone marrow transplantation was performed on 12 male and eight female patients ranging from 3 to 48 years old (mean age, 25 years) for treatment of various forms of leukemia (n = 12), severe aplastic anemia (n = 6), Fanconi's syndrome (n = 1), and paroxysmal nocturnal hemoglobinuria (n = 1). Sixteen patients (80%) had abnormal CT findings. The predominant patterns of abnormality on high-resolution CT scans were small centrilobular nodules (10/20, 50%), air-space consolidation (7/20, 35%), ground-glass opacities (6/20, 30%), and bronchial wall thickening (6/20, 30%). The abnormalities were distributed in the central and peripheral areas of the lungs in nine cases, only in the periphery in five cases, and only in the central regions in two cases. The abnormalities were bilateral and asymmetric in distribution in 13 patients, bilateral and symmetric in two patients, and unilateral in one patient. CONCLUSION: The most common high-resolution CT findings in patients with respiratory syncytial virus pneumonia after bone marrow transplantation consist of small centrilobular nodules and multifocal areas of consolidation and ground-glass opacities in a bilateral asymmetric distribution.

    High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Publishing Authors By Initials

    el gasparettoEL Gasparetto,dl escuissatoDL Escuissato,e marchioriE Marchiori,s onoS Ono,rl frare e silvaRL Frare e Silva,nl müllerNL Müller,

    For similar tomography, x-ray computed research abstracts see: tomography, x-ray computed research

    PUBMED ID PMID:

    MEDLINE DATE:

    High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJR. American journal of roentgenology

    VOLUME: 182

    Page Numbers: 1133-7

    Journal Abbreviation:

    ISSN: 0361-803X

    DAY: 15

    MONTH: May

    YEAR: 2004

    High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7708173

    High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Keywords Mesh Terms:

    KEYWORDS: Tomography, X-Ray Computed

    MESH TERMS: methods

    Chemical & Substance for Abstract: High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation.

    AFFILIATION: Department of Radiology, University of Paraná, Paraná, Brazil.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJR Am J Roentgenol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    High-resolution CT findings of respiratory syncytial virus pneumonia after bone marrow transplantation Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News