Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

High-frequency ultrasonic imaging of the anterior segment using an annular array transducer.

High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Abstract Text:

    ronald h silvermanRonald H Silverman,jeffrey a ketterlingJeffrey A Ketterling,d jackson colemanD Jackson Coleman,

    OBJECTIVE: Very high-frequency ultrasound (VHFU; >35 megahertz [MHz]) allows imaging of anterior segment structures of the eye with a resolution of less than 40 microm. The low focal ratio of VHFU transducers, however, results in a depth of field (DOF) of less than 1 mm. The aim was to develop a high-frequency annular array transducer for ocular imaging with improved DOF, sensitivity, and resolution compared with conventional transducers. DESIGN: Experimental study. PARTICIPANTS: Cadaver eyes, ex vivo cow eyes, in vivo rabbit eyes. METHODS: A spherically curved annular array ultrasound transducer was fabricated. The array consisted of 5 concentric rings of equal area, had an overall aperture of 6 mm, and a geometric focus of 12 mm. The nominal center frequency of all array elements was 40 MHz. An experimental system was designed in which a single array element was pulsed and echo data were recorded from all elements. By sequentially pulsing each element, echo data were acquired for all 25 transmit-and-receive annuli combinations. The echo data then were focused synthetically and composite images were produced. Transducer operation was tested by scanning a test object consisting of a series of 25-microm diameter wires spaced at increasing range from the transducer. Imaging capabilities of the annular array were demonstrated in ex vivo bovine, in vivo rabbit, and human cadaver eyes. MAIN OUTCOME MEASURES: Depth of field, resolution, and sensitivity. RESULTS: The wire scans verified the operation of the array and demonstrated a 6.0-mm DOF, compared with the 1.0-mm DOF of a conventional single-element transducer of comparable frequency, aperture, and focal length. B-mode images of ex vivo bovine, in vivo rabbit, and cadaver eyes showed that although the single-element transducer had high sensitivity and resolution within 1 to 2 mm of its focus, the array with synthetic focusing maintained this quality over a 6-mm DOF. CONCLUSIONS: An annular array for high-resolution ocular imaging has been demonstrated. This technology offers improved DOF, sensitivity, and lateral resolution compared with single-element fixed focus transducers currently used for VHFU imaging of the eye.

    High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Publishing Authors By Initials

    rh silvermanRH Silverman,ja ketterlingJA Ketterling,dj colemanDJ Coleman,

    For similar equipment and supplies: transducers research abstracts see: equipment and supplies: transducers research

    PUBMED ID PMID:

    MEDLINE DATE:

    High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: Ophthalmology

    VOLUME: 114

    Page Numbers: 816-22

    Journal Abbreviation: Ophthalmology

    ISSN: 1549-4713

    DAY: 30

    MONTH: 11

    YEAR: 2006

    High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7802443

    High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Keywords Mesh Terms:

    KEYWORDS: Transducers

    MESH TERMS: ultrasonography

    Chemical & Substance for Abstract: High-frequency ultrasonic imaging of the anterior segment using an annular array transducer. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for High-frequency ultrasonic imaging of the anterior segment using an annular array transducer.

    AFFILIATION: Department of Ophthalmology, Weill Medical College of Cornell University, New York, New York 10021, USA. ros2012@med.cornell.edu

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NEI

    GRANT: R03 EY014371-01

    ACRONYM: EY

    MEDLINETA: Ophthalmology

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    High-frequency ultrasonic imaging of the anterior segment using an annular array transducer Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News