Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction.

Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Abstract Text:

    janine m lupoJanine M Lupo,michael c leeMichael C Lee,eric t hanEric T Han,soonmee chaSoonmee Cha,susan m changSusan M Chang,mitchel s bergerMitchel S Berger,sarah j nelsonSarah J Nelson,

    PURPOSE: To investigate changes in image and dynamic signal-to-noise ratios (SNRs) of the DeltaR2* curve, as well as magnetic susceptibility-induced artifacts between a standard quadrature head coil and an eight-channel phased-array coil with and without sensitivity-encoding (SENSE) at 3T, compared to the current clinical standard head coil acquisition at 1.5T. MATERIALS AND METHODS: Dynamic susceptibility contrast (DSC) perfusion MRI was performed on 80 brain tumor patients using a gradient-echo, echo-planar imaging (EPI) sequence. Image and dynamic SNR were compared between 1.5T and 3T field strengths, a quadrature and eight-channel phased-array coil, and a conventional vs. partially parallel EPI acquisition with SENSE reconstruction. The amount of geometric distortion and signal dropout was quantified and compared between conventional and SENSE EPI acquisitions within the same exam at 3T. RESULTS: An initial 2.6-fold elevation in dynamic SNR was observed in normal-appearing white matter when doubling the field strength (P < 0.001), with an additional 1.7-fold increase found when employing an eight-channel phased-array coil (P < 0.002). Compared to the standard 3T eight-channel coil acquisition, the implementation of SENSE reduced the number of voxels experiencing large anterior shifts in the phase-encode direction, lowered the volume of signal dropout by 2.0-11.5%, and allowed a 1.4-fold increase in slice coverage, while only decreasing the dynamic SNR by 22%. CONCLUSION: SENSE EPI at 3T yielded a significant improvement in dynamic SNR over the 1.5T acquisitions. A significant reduction in magnetic susceptibility-induced artifacts was achieved with SENSE EPI compared to the standard EPI eight-channel coil acquisition at 3T.

    Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Publishing Authors By Initials

    jm lupoJM Lupo,mc leeMC Lee,et hanET Han,s chaS Cha,sm changSM Chang,ms bergerMS Berger,sj nelsonSJ Nelson,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: Journal of magnetic resonance imaging : JMRI

    VOLUME: 24

    Page Numbers: 520-9

    Journal Abbreviation:

    ISSN: 1053-1807

    DAY: 3

    MONTH: Sep

    YEAR: 2006

    Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9105850

    Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction.

    AFFILIATION: Department of Radiology, University of California San Francisco, San Francisco, California 94158, USA. janinel@mrsc.ucsf.edu

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Magn Reson Imaging

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News