Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis.

Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Abstract Text:

    zheng-han yangZheng-Han Yang,xiao-hua yeXiao-Hua Ye,ye tanYe Tan,min zhangMin Zhang,ming-zhu zhouMing-Zhu Zhou,jing-xia xieJing-Xia Xie,min chenMin Chen,cheng zhouCheng Zhou,

    OBJECTIVE: To investigate the role of perfusion-weighted magnetic resonance imaging (MRI) in evaluation of cirrhotic liver. METHODS: With a 4F catheter, 1% diluted carbon tetrachloride (1 ml/kg) was selectively injected into right or left hepatic artery of 12 dogs fortnightly. The half liver into which carbon tetrachloride was injected was called as study side (SS), while the other half liver without carbon tetrachloride injection was called as study control side (SCS). Conventional and perfusion-weighted MRI were performed in every 4 weeks. Via a 4F catheter, 5ml gadolinium diethylentriamine pentaaceti acid (Gd-DTPA) dilution was injected into superior mesenteric artery at the 5th scan. The signal intensity-time curves of SS, SCS, and portal vein were completed in MR workstation. The maximal relative signal increase (MRSI), peak time (tp), and slope of the curves were measured. RESULTS: On conventional MR images, no abnormalities of externality and signal intensity were observed in both SS and SCS of liver at each stage. The mean tp, MRSI, and slope of intensity-time curves in normal liver were 10.56 seconds, 1.01, and 10.23 arbitrary unit (au)/s, respectively. Three parameters of curves didn't show obvious change in SCS of liver at every stage. Abnormal perfusion curves occurred in SS of liver at the 12th week after the 1st injection. The abnormality of perfusion curve in SS was more and more serious as the times of injection increased. The mean tp, MRSI, and slope intensity-time curves in SS of liver were 19.45 seconds, 0.43, and 3.60 au/s respectively at the 24th week. CONCLUSION: Perfusion-weighted imaging can potentially provide information about portal perfusion of hepatic parenchyma, and to some degree, reflect the severity of cirrhosis.

    Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Publishing Authors By Initials

    zh yangZH Yang,xh yeXH Ye,y tanY Tan,m zhangM Zhang,mz zhouMZ Zhou,jx xieJX Xie,m chenM Chen,c zhouC Zhou,

    For similar diagnosis: diagnostic techniques and procedures: diagnostic imaging: magnetic resonance imaging research abstracts see: diagnosis: diagnostic techniques and procedures: diagnostic imaging: magnetic resonance imaging research

    PUBMED ID PMID:

    MEDLINE DATE:

    Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Chinese medical sciences journal = Chung-kuo i hsü

    VOLUME: 21

    Page Numbers: 252-7

    Journal Abbreviation: Chin. Med. Sci. J.

    ISSN: 1001-9294

    DAY: 29

    MONTH: Dec

    YEAR: 2006

    Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9112559

    Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Keywords Mesh Terms:

    KEYWORDS: Magnetic Resonance Imaging

    MESH TERMS: methods

    Chemical & Substance for Abstract: Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis. Information

    Substance Name: Gadolinium DTPA

    Registry Number: 80529-93-7

    Grant and Affiliation Information for Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis.

    AFFILIATION: Department of Radiology, Beijing Hospital, Fifth Clinical Medical School of Peking University, Beijing 100730. cjr.yangzhenghan@vip.163.com

    Country: China

    China Research PublicationChina Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Chin Med Sci J

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Evaluation of cirrhotic liver with perfusion-weighted magnetic resonance imaging: a preliminary experimental study in animal models with half-liver cirrhosis Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News