Efficacy and long-term patency of fenestrated amplatzer devices in children.

Efficacy and long-term patency of fenestrated amplatzer devices in children. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Efficacy and long-term patency of fenestrated amplatzer devices in children. Abstract Text:

    astrid e lammersAstrid E Lammers,graham derrickGraham Derrick,sheila g haworthSheila G Haworth,philipp bonhoefferPhilipp Bonhoeffer,robert yatesRobert Yates,astrid e lammersAstrid E Lammers,graham derrickGraham Derrick,sheila g haworthSheila G Haworth,philipp bonhoefferPhilipp Bonhoeffer,robert yatesRobert Yates,

    INTRODUCTION: Novel transcatheter techniques to control interatrial communications exist. Devices with restrictive fenestrations can be implanted to maintain patency of an atrial septostomy, or reduce an interatrial communication. Experience with these devices in children is limited. PATIENTS AND METHODS: Fenestrated atrial septal devices were implanted into 10 children (5 male, age 1.5-15.5 years). Devices were modified by the manufacturer (MM, n = 6), or by a modification of an atrial septal occlusion device by the operator (OM, n = 4). Seven devices were implanted after atrial septal puncture and septostomy for severe symptomatic pulmonary hypertension (PHT) [4 heart failure, 3 syncope], according to World Health Organisation Guidelines. Two devices were implanted to reduce left to right shunting through large atrial septal defects with associated PHT. One device was implanted acutely to offload the left atrium during extracorporal circulatory support prior to heart transplantation. Warfarin (n = 5), aspirin (n = 4), or heparin (n = 1) were used for prevention of fenestration thrombosis. RESULTS: Symptoms in all patients with PHT improved after implantation; syncope recurred with fenestration occlusion in one patient. Nine patients were followed up to a mean of 26 months. Five devices (all MM; warfarin n = 4, aspirin n = 1) remained patent on echocardiography. Fenestrations occluded in 4 children after median follow-up of 10 months (MM n = 1, OM n = 3, warfarin n = 1, aspirin n = 3). CONCLUSIONS: Implantation of fenestrated atrial devices is feasible and effective; but the occlusion rate is high. Further research on fenestrated atrial septal devices with better long-term patency, and effective antithrombotic drug treatment is necessary.

    Efficacy and long-term patency of fenestrated amplatzer devices in children. Publishing Authors By Initials

    ae lammersAE Lammers,g derrickG Derrick,sg haworthSG Haworth,p bonhoefferP Bonhoeffer,r yatesR Yates,ae lammersAE Lammers,g derrickG Derrick,sg haworthSG Haworth,p bonhoefferP Bonhoeffer,r yatesR Yates,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Efficacy and long-term patency of fenestrated amplatzer devices in children. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Catheterization and cardiovascular interventions :

    VOLUME: 70

    Page Numbers: 578-84

    Journal Abbreviation:

    ISSN: 1522-1946

    DAY: 1

    MONTH: Oct

    YEAR: 2007

    Efficacy and long-term patency of fenestrated amplatzer devices in children. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 100884139

    Efficacy and long-term patency of fenestrated amplatzer devices in children. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Efficacy and long-term patency of fenestrated amplatzer devices in children. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Efficacy and long-term patency of fenestrated amplatzer devices in children.

    AFFILIATION: Department of Pediatric Cardiology, Great Ormond Street Hospital for Children, Great Ormond Street, London, United Kingdom.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Catheter Cardiovasc Interv

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Efficacy and long-term patency of fenestrated amplatzer devices in children Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News