Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Effects of stent design parameters on normal artery wall mechanics.

Effects of stent design parameters on normal artery wall mechanics. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Effects of stent design parameters on normal artery wall mechanics. Abstract Text:

    julian bedoyaJulian Bedoya,clark a meyerClark A Meyer,lucas h timminsLucas H Timmins,michael r morenoMichael R Moreno,james e mooreJames E Moore,

    A stent is a device designed to restore flow through constricted arteries. These tubular scaffold devices are delivered to the afflicted region and deployed using minimally invasive techniques. Stents must have sufficient radial strength to prop the diseased artery open. The presence of a stent can subject the artery to abnormally high stresses that can trigger adverse biologic responses culminating in restenosis. The primary aim of this investigation was to investigate the effects of varying stent "design parameters" on the stress field induced in the normal artery wall and the radial displacement achieved by the stent. The generic stent models were designed to represent a sample of the attributes incorporated in present commercially available stents. Each stent was deployed in a homogeneous, nonlinear hyperelastic artery model and evaluated using commercially available finite element analysis software. Of the designs investigated herein, those employing large axial strut spacing, blunted corners, and higher amplitudes in the ring segments induced high circumferential stresses over smaller areas of the artery's inner surface than all other configurations. Axial strut spacing was the dominant parameter in this study, i.e., all designs employing a small stent strut spacing induced higher stresses over larger areas than designs employing the large strut spacing. Increasing either radius of curvature or strut amplitude generally resulted in smaller areas exposed to high stresses. At larger strut spacing, sensitivity to radius of curvature was increased in comparison to the small strut spacing. With the larger strut spacing designs, the effects of varying amplitude could be offset by varying the radius of curvature and vice versa. The range of minimum radial displacements from the unstented diastolic radius observed among all designs was less than 90 microm. Evidence presented herein suggests that stent designs incorporating large axial strut spacing, blunted corners at bends, and higher amplitudes exposed smaller regions of the artery to high stresses, while maintaining a radial displacement that should be sufficient to restore adequate flow.

    Effects of stent design parameters on normal artery wall mechanics. Publishing Authors By Initials

    j bedoyaJ Bedoya,ca meyerCA Meyer,lh timminsLH Timmins,mr morenoMR Moreno,je mooreJE Moore,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Effects of stent design parameters on normal artery wall mechanics. Journal Published:

    PUBLICATION TYPE: Research Support, N.I.H., Extr

    Journal: Journal of biomechanical engineering

    VOLUME: 128

    Page Numbers: 757-65

    Journal Abbreviation:

    ISSN: 0148-0731

    DAY: 3

    MONTH: Oct

    YEAR: 2006

    Effects of stent design parameters on normal artery wall mechanics. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7909584

    Effects of stent design parameters on normal artery wall mechanics. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Effects of stent design parameters on normal artery wall mechanics. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Effects of stent design parameters on normal artery wall mechanics.

    AFFILIATION: Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843-3120, USA.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: J Biomech Eng

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Effects of stent design parameters on normal artery wall mechanics Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News