[Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.]

[Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Abstract Text:

    yohsuke kusanoYohsuke Kusano,shinichi minoharaShinichi Minohara,takayoshi ishiiTakayoshi Ishii,kengo fujimoriKengo Fujimori,noritoshi ikedaNoritoshi Ikeda,takanori kondoTakanori Kondo,hideo tubukuHideo Tubuku,atsushi itoAtsushi Ito,hirohisa uchidaHirohisa Uchida,

    In order to support a routine QA of the CT number for treatment planning, we developed a phantom and a sample holder for easy handling. At most particle radiotherapy facilities in Japan, the CT number is calibrated by the poly-binary calibration method using liquid samples of 100% ethanol and 40% K(2)HPO(4) which are set in a cylindrical water phantom. However it is hard to remove air bubbles from the calibration liquid sample and maintain its stable concentration for a long time. So much time is needed for QA of the CT number. The new sample holder, which we developed, was able to keep a stable concentration of the liquid for more than 300 days. Consequently, the CT number of each sample, which was set in a water equivalent solid phantom, was the same as the CT number in a water phantom within 7 HU. In addition, we developed software which could measure the CT number of each sample semi-automatically and could calculate the calibration coefficients between the CT number and water equivalent length (WEL). Using this software, we could check the calibration result instantly at the time of CT data acquisition. These tools should be useful to carry out calibration of the CT-WEL routinely in a short time.

    [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Publishing Authors By Initials

    y kusanoY Kusano,s minoharaS Minohara,t ishiiT Ishii,k fujimoriK Fujimori,n ikedaN Ikeda,t kondoT Kondo,h tubukuH Tubuku,a itoA Ito,h uchidaH Uchida,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Igaku butsuri : Nihon Igaku Butsuri Gakkai kikansh

    VOLUME: 26

    Page Numbers: 163-72

    Journal Abbreviation:

    ISSN: 1345-5354

    DAY: 19

    MONTH: 07

    YEAR: 2006

    [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Information

    Number of References:

    LANGUAGE: jpn

    NlmUniqueID: 101125977

    [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.] Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for [Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner.]

    AFFILIATION: Accelerator Engineering Corporation, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan. kusano@aec-beam.co.jp.

    Country: Japan

    Japan Research PublicationJapan Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Igaku Butsuri

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Development of the QA/QC-tools for CT number calibration of the treatment planning CT-scanner Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News