Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

[Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography]

[Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Abstract Text:

    bu-xing chenBu-xing Chen,feng-yun maFeng-yun Ma,wei luoWei Luo,wen-li xieWen-li Xie,xi-zhe zhaoXi-zhe Zhao,shu-hong sunShu-hong Sun,feng wangFeng Wang,xu-mei guoXu-mei Guo,xiao-wen chuXiao-wen Chu,

    OBJECTIVE: To evaluate coronary artery atherosclerotic plaque characteristics and changes post coronary stenting by optical coherence tomography (OCT). METHODS: OCT images were obtained in 22 diseased coronary vessels after coronary angiography or percutaneous coronary interventions (PCI) in 20 patients and in 23 stents [7 sirolimus-eluting stents (SES) follow up at 4-29 months post stenting and 8 bare mental stents (BMS) at 4-35 months post stenting, 8 stents immediately after PCI]. RESULTS: All 22 vessels and 23 stents OCT images were successfully acquired. Two thromboses, 8 fibrous, 9 lipid-rich and 3 calcium plaques as well as 3 plaque ruptures were visualized by OCT. No significant neointimal proliferation and restenosis were found in SES stents and some struts were not covered with neointima even at 29 months post stenting. Significant neointimal proliferation on surfaces of stent struts were visualized in all 8 BMS stents and restenosis was detected in 3 BMS stents. OCT images obtained immediately after PCI showed that 3 stents were well positioned, tissue prolapse between coronary stent struts occurred in 4 stents and stent dissociation with vessel wall could be seen in 1 stent. CONCLUSIONS: OCT imaging can clearly visualize different types of atherosclerotic plaques. By providing detailed information on plaque characteristics, this technique might help cardiologists in choosing suitable stents and guiding preventive therapy for patients with coronary heart disease.

    [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Publishing Authors By Initials

    bx chenBX Chen,fy maFY Ma,w luoW Luo,wl xieWL Xie,xz zhaoXZ Zhao,sh sunSH Sun,f wangF Wang,xm guoXM Guo,xw chuXW Chu,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Zhonghua xin xue guan bing za zhi [Chinese journal

    VOLUME: 34

    Page Numbers: 130-3

    Journal Abbreviation:

    ISSN: 0253-3758

    DAY: 21

    MONTH: Feb

    YEAR: 2006

    [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Information

    Number of References:

    LANGUAGE: chi

    NlmUniqueID: 7910682

    [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography] Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for [Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography]

    AFFILIATION: Department of Cardiology, Beijing Electric Power Hospital, Beijing 100073, China. chbux@sohu.com

    Country: China

    China Research PublicationChina Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Zhonghua Xin Xue Guan Bing Za

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Coronary artery atherosclerotic plaque and stent visualizations by optical coherence tomography Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News