Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps.

Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Abstract Text:

    m macariM Macari,a milanoA Milano,m lavelleM Lavelle,p bermanP Berman,a j megibowA J Megibow,

    OBJECTIVE: We compared the findings of time-efficient CT colonography with complete two-dimensional (2D) and three-dimensional (3D) CT colonography and conventional colonoscopy in detecting colorectal polyps. SUBJECTS AND METHODS: Forty-two patients undergoing colonoscopy screening were examined with CT colonography before endoscopy. Data were examined following one of two methods. In method 1, axial 2D data sets were examined in a cine mode. If findings were suggestive of abnormality, focal areas were examined with 3D CT colonography. In method 2, data sets were examined exactly as in method 1, and subsequent to that review, data sets were examined with simultaneous 3D "fly-through" CT colonography (surface-rendered images) and multiplanar reformatted images. The time required to examine CT colonography using each technique was recorded and abnormal findings were documented. Results of methods 1 and 2 were compared with findings on colonoscopy. RESULTS: Colonoscopy detected 16 polyps in 13 patients (polyp size, 2-10 mm). Ten polyps measured 5 mm or less, five measured between 6 and 9 mm, and one measured 10 mm or more. Using method 1, two of 10 polyps measuring less than 5 mm, three of five polyps measuring between 6 and 9 mm, and one polyp measuring 10 mm were detected. We noted no false-positive polyps. Average evaluation time was 16 min. With method 2, the same polyps were seen as with method 1. No additional polyps were detected, and the average evaluation time was 40 min. CONCLUSION: Axial 2D CT colonography can be performed quickly and is comparable with complete 2D and 3D CT colonography in detecting colorectal polyps.

    Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Publishing Authors By Initials

    m macariM Macari,a milanoA Milano,m lavelleM Lavelle,p bermanP Berman,aj megibowAJ Megibow,

    For similar tomography, x-ray computed research abstracts see: tomography, x-ray computed research

    PUBMED ID PMID:

    MEDLINE DATE:

    Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJR. American journal of roentgenology

    VOLUME: 174

    Page Numbers: 1543-9

    Journal Abbreviation:

    ISSN: 0361-803X

    DAY: 15

    MONTH: Jun

    YEAR: 2000

    Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7708173

    Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Keywords Mesh Terms:

    KEYWORDS: Tomography, X-Ray Computed

    MESH TERMS: radiography

    Chemical & Substance for Abstract: Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps.

    AFFILIATION: Department of Radiology, New York University Medical Center, NY 10016, USA.

    Country: UNITED STATES

    UNITED STATES Research PublicationUNITED STATES Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJR Am J Roentgenol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Comparison of time-efficient CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News