Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis.

Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Abstract Text:

    antonius rohlmannAntonius Rohlmann,nagananda k burraNagananda K Burra,thomas zanderThomas Zander,georg bergmannGeorg Bergmann,

    A bilateral dynamic stabilization device is assumed to alter favorable the movement and load transmission of a spinal segment without the intention of fusion of that segment. Little is known about the effect of a posterior dynamic fixation device on the mechanical behavior of the lumbar spine. Muscle forces were disregarded in the few biomechanical studies published. The aim of this study was to determine how the spinal loads are affected by a bilateral posterior dynamic implant compared to a rigid fixator which does not claim to maintain mobility. A paired monosegmental posterior dynamic implant was inserted at level L3/L4 in a validated finite element model of the lumbar spine. Both a healthy and a slightly degenerated disc were assumed at implant level. Distraction of the bridged segment was also simulated. For comparison, a monosegmental rigid fixation device as well as the effect of implant stiffness on intersegmental rotation were studied. The model was loaded with the upper body weight and muscle forces to simulate the four loading cases standing, 30 degrees flexion, 20 degrees extension, and 10 degrees axial rotation. Intersegmental rotations, intradiscal pressure and facet joint forces were calculated at implant level and at the adjacent level above the implant. Implant forces were also determined. Compared to an intact spine, a dynamic implant reduces intersegmental rotation at implant level, decreases intradiscal pressure in a healthy disc for extension and standing, and decreases facet joint forces at implant level. With a rigid implant, these effects are more pronounced. With a slightly degenerated disc intersegmental rotation at implant level is mildly increased for extension and axial rotation and intradiscal pressure is strongly reduced for extension. After distraction, intradiscal pressure values are markedly reduced only for the rigid implant. At the adjacent level L2/L3, a posterior implant has only a minor effect on intradiscal pressure. However, it increases facet joint forces at this level for axial rotation and extension. Posterior implants are mostly loaded in compression. Forces in the implant are generally higher in a rigid fixator than in a dynamic implant. Distraction strongly increases both axial and shear forces in the implant. A stiffness of the implant greater than 1,000 N/mm has only a minor effect on intersegmental rotation. The mechanical effects of a dynamic implant are similar to those of a rigid fixation device, except after distraction, when intradiscal pressure is considerably lower for rigid than for dynamic implants. Thus, the results of this study demonstrate that a dynamic implant does not necessarily reduce axial spinal loads compared to an un-instrumented spine.

    Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Publishing Authors By Initials

    a rohlmannA Rohlmann,nk burraNK Burra,t zanderT Zander,g bergmannG Bergmann,

    For similar biomechanics: weight-bearing research abstracts see: biomechanics: weight-bearing research

    PUBMED ID PMID:

    MEDLINE DATE:

    Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: European spine journal : official publication of t

    VOLUME: 16

    Page Numbers: 1223-31

    Journal Abbreviation:

    ISSN: 0940-6719

    DAY: 6

    MONTH: 01

    YEAR: 2007

    Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9301980

    Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Keywords Mesh Terms:

    KEYWORDS: Weight-Bearing

    MESH TERMS: physiology

    Chemical & Substance for Abstract: Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis.

    AFFILIATION: Biomechanics Laboratory, Orthopaedic Hospital, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Hindenburgdamm 30, 12203 Berlin, Germany. rohlmann@biomechanik.de

    Country: Germany

    Germany Research PublicationGermany Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Eur Spine J

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysis Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News