Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri.

Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Abstract Text:

    luhua zhaoLuhua Zhao,xinyong zhangXinyong Zhang,xiying tanXiying Tan,menghua wuMenghua Wu,bingren xiangaBingren Xianga,

    In our studies, micellar electrokinetic capillary chromatography (MEKC) was employed in fingerprint analysis of Cnidium monnieri for the first time. Average chromatography of 10 batches Cnidium monnieri from Jiangsu province, China, which have long been considered as the original and genuine herbal medicine, was first established as the characteristic fingerprint. Within 25 min the major effective components were separated by 18 mM borate, 12 mM phosphate and 50 mM SDS (pH 9.2) containing 20% methanol. The relative standard deviations of migration times and peak areas were less than 5%. As a new approach of fingerprint, MKCE was compared to the conventional approach-HPLC in our experiments. The fingerprint developed by HPLC comprised 8 peaks that were collected within 40 min. Relative standard deviation (RSD) values of retention times of corresponding peaks in HPLC analysis were very small (maximum 3% and average 0.9%). In conclusion, each two methods had its advantages and disadvantages. Furthermore, besides HPLC, MEKC as a feasible method, could be used in the development of fingerprint of Cnidium monnieri.

    Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Publishing Authors By Initials

    l zhaoL Zhao,x zhangX Zhang,x tanX Tan,m wuM Wu,b xiangaB Xianga,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Chemical & pharmaceutical bulletin

    VOLUME: 54

    Page Numbers: 897-901

    Journal Abbreviation: Chem. Pharm. Bull.

    ISSN: 0009-2363

    DAY: 6

    MONTH: Jun

    YEAR: 2006

    Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 377775

    Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri.

    AFFILIATION: Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education, P.R. China.

    Country: Japan

    Japan Research PublicationJapan Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Chem Pharm Bull (Tokyo)

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Comparison of Micellar Electrokinetic Capillary Chromatography and High Performance Liquid Chromatography on Fingerprint of Cnidium monnieri Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News