Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling.

Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Abstract Text:

    ABSTRACT: BACKGROUND: Although the PBS-IIc SELDI-TOF MS apparatus has been extensively used in the search for better biomarkers, issues have been raised concerning the semi-quantitative nature of the technique and its reproducibility. To overcome these limitations, a new SELDI-TOF MS instrument has been introduced: the PCS 4000 series. Changes in this apparatus compared to the older one are a.o. an increased dynamic range of the detector, an adjusted configuration of the detector sensitivity, a raster scan that ensures more complete desorption coverage and an improved detector attenuation mechanism. In the current study, we evaluated the performance of the old PBS-IIc and new PCS 4000 series generation SELDI-TOF MS apparatus. METHODS: To this end, two different sample sets were profiled after which the same ProteinChip arrays were analysed successively by both instruments. Generated spectra were analysed by the associated software packages. The performance of both instruments was evaluated by assessment of the number of peaks detected in the two sample sets, the biomarker potential and reproducibility of generated peak clusters, and the number of peaks detected following serum fractionation. RESULTS: We could not confirm the claimed improved performance of the new PCS 4000 instrument, as assessed by the number of peaks detected, the biomarker potential and the reproducibility. However, the PCS 4000 instrument did prove to be of superior performance in peak detection following profiling of serum fractions. CONCLUSION: As serum fractionation facilitates detection of low abundant proteins through reduction of the dynamic range of serum proteins, it is now increasingly applied in the search for new potential biomarkers. Hence, although the new PCS 4000 instrument did not differ from the old PBS-IIc apparatus in the analysis of crude serum, its superior performance after serum fractionation does hold promise for improved biomarker detection and identification.

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Publishing Authors By Initials

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: BMC medical genomics

    VOLUME: 1

    Page Numbers: 4

    Journal Abbreviation:

    ISSN: 1755-8794

    DAY: 31

    MONTH: 01

    YEAR: 2008

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 101319628

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling.

    AFFILIATION: Department of Pharmacy & Pharmacology, The Netherlands Cancer Institute/Slotervaart Hospital, Amsterdam, The Netherlands. Marie-Christine.Gast@slz.nl.

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: BMC Med Genomics

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Comparing the old and new generation SELDI-TOF MS: implications for serum protein profiling Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News