Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

-Zai-Ming Jin Researcher Activity Profile

Research Author Detailed Information 

profile photo of Zai-Ming JinZai-ming jin researcher

Zai-Ming Jin Publication Rate By Year

Zai-Ming Jin has published 1 paper(s) in 1991, 1 paper(s) in 1992, 3 paper(s) in 1993, 1 paper(s) in 1994, 2 paper(s) in 1995, 1 paper(s) in 1996, 3 paper(s) in 1997, 3 paper(s) in 1998, 1 paper(s) in 1999, 1 paper(s) in 2000, 2 paper(s) in 2001, 7 paper(s) in 2002, 4 paper(s) in 2003, 6 paper(s) in 2004, 2 paper(s) in 2005, 6 paper(s) in 2006, 3 paper(s) in 2007, 1 paper(s) in 2008, for a total of 48 research publications in total.

Zai-Ming Zm Jin Author Information

LAST NAME: jin

FIRST NAME: Zai-ming

INITIALS: zm

AFFILIATION:

Papers

Zai-Ming Jin's Publication Record

  1. [The influence of postburn administration of rhGH on the host inflammatory response] Year Published: 2003
  2. Department of Burns, Rui Jin Hospital, The Second Medical University of Shanghai, PR China.
  3. [Clinical significance of PML/RARalpha isoforms in adult patients with acute promyelocytic leukemia] Year Published: 2005
  4. Department of Hematology, The First Affiliated Hospital of Suzhou University, Jiangsu Institute of Hematology, Suzhou 215006, China. ainingsun@hotmail.com
  5. [Abnormal expression of cCD79a/cCD22 in acute myeloid leukemia with t (8;21)] Year Published: 2006
  6. First Affiliated Hospital of Soochow University, Jiangsu Institute of Hematology, Suzhou 215006, China.
  7. [Clinical study on haploid HLA-matched hematopoietic stem cell transplantation for treatment of malignant hematological disease] Year Published: 2006
  8. The First Affiliated Hospital of Soochow University, Jiangsu Institute of Hematology, Jiangsu, Suzhou 215006, P. R. China.
  9. [In Process Citation] Year Published: 2007
  10. First Affiliated Hospital, Medical College, Zhejiang University, Hangzhou 310003, China.
  11. [Preliminary study of the effect of HLA-Cw on haploidentical hematopoietic stem cell transplantation] Year Published: 2007
  12. Department of Hematology, the First Affiliated Hospital of Suzhou University, Jiangsu Institute of Hematology, Suzhou 215006, China.
  13. [Role of CD28/CTLA-4 costimulators in immune pathophysiology of aplastic anemia] Year Published: 2008
  14. First Affiliated Hospital of Soochow University, Jiangsu Insititute of Hematology, Suzhou 215006, China.
  15. A general axisymmetric contact mechanics model for layered surfaces, with particular reference to artificial hip joint replacements. Year Published: 2000
  16. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  17. Analysis and modelling of wear of cobalt-chrome alloys in a pin-on-plate test for a metal-on-metal total hip replacement. Year Published: 2001
  18. Department of Mechanical and Medical Engineering, University of Bradford, West Yorkshire, UK.
  19. Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion. Year Published: 2001
  20. Department of Mechanical and Medical Engineering, University of Bradford, West Yorkshire BD7 1DP, UK.
  21. Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion. Year Published: 2002
  22. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  23. Contact mechanics of a novel metal-on-metal total hip replacement. Year Published: 2002
  24. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  25. Importance of pin geometry on pin-on-plate wear testing of hard-on-hard bearing materials for artificial hip joints. Year Published: 2002
  26. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  27. Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements. Year Published: 2002
  28. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  29. Analysis of elastohydrodynamic lubrication in a novel metal-on-metal hip joint replacement. Year Published: 2002
  30. Analysis of contact mechanics in ceramic-on-ceramic hip joint replacements. Year Published: 2002
  31. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  32. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Year Published: 2002
  33. Department of Mechanical and Medical Engineering, University of Bradford, Bradford, UK.
  34. Elastohydrodynamic lubrication analysis of a functionally graded layered bearing surface, with particular reference to 'cushion form bearings' for artificial knee joints. Year Published: 2003
  35. School of Engineering, Design and Technology, University of Bradford, Bradford, UK.
  36. Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing. Year Published: 2003
  37. School of Engineering, Design and Technology, University of Bradford, Bradford, UK.
  38. Analysis of contact mechanics in McKee-farrar metal-on-metal hip implants. Year Published: 2003
  39. Department of Mechanical and Medical Engineering, University of Bradford, Bradford, UK.
  40. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces. Year Published: 2004
  41. School of Engineering, Design and Technology, University of Bradford, Bradford, UK.
  42. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement. Year Published: 2004
  43. Medical Engineering, University of Bradford, School of Engineering, Design and Technology, Bradford, UK.
  44. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles. Year Published: 2004
  45. Medical Engineering, School of Engineering, Design and Technology, University of Bradford, Bradford, UK.
  46. Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing. Year Published: 2004
  47. Medical Engineering, School of Engineering, Design and Technology, University of Bradford, Bradford BD7 1DP, UK.
  48. Determination of contact area in 'cushion form' bearings for artificial hip joints. Year Published: 1991
  49. Department of Mechanical Engineering, University of Leeds.
  50. Design considerations for cushion form bearings in artificial hip joints. Year Published: 1992
  51. Department of Mechanical Engineering, University of Leeds.
  52. The effect of porosity of articular cartilage on the lubrication of a normal human hip joint. Year Published: 1993
  53. Department of Mechanical Engineering, University of Leeds.
  54. A full numerical solution to the problem of microelastohydrodynamic lubrication of a stationary compliant wavy layered surface firmly bonded to a rigid substrate with particular reference to human synovial joints. Year Published: 1993
  55. Department of Mechanical Engineering, University of Leeds.
  56. Friction and lubrication in cushion form bearings for artificial hip joints. Year Published: 1993
  57. Department of Mechanical Engineering, University of Leeds.
  58. Stress analysis of cushion form bearings for total hip replacements. Year Published: 1994
  59. Department of Mechanical Engineering, University of Leeds.
  60. Contact pressure prediction in total knee joint replacements. Part 1: General elasticity solution for elliptical layered contacts. Year Published: 1995
  61. Department of Mechanical Engineering, University of Leeds.
  62. Contact pressure prediction in total knee joint replacements. Part 2: Application to the design of total knee joint replacements. Year Published: 1995
  63. Department of Mechanical Engineering, University of Leeds.
  64. Determination of lubricating film thickness for permeable hydrogel and non-permeable polyurethane layers bonded to a rigid substrate with particular reference to cushion form hip joint replacements. Year Published: 1996
  65. Department of Mechanical Engineering, University of Leeds.
  66. Experimental and theoretical study of the contact mechanics of five total knee joint replacements. Year Published: 1997
  67. Department of Mechanical Engineering, University of Leeds.
  68. Finite element analysis of a total knee replacement by using Gauss point contact constraints. Year Published: 1997
  69. Department of Mechanical and Manufacturing Engineering, University of Bradford.
  70. Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus. Year Published: 1997
  71. Department of Mechanical and Manufacturing Engineering, University of Bradford.
  72. Friction of composite cushion bearings for total knee joint replacements under adverse lubrication conditions. Year Published: 1998
  73. Department of Mechanical Engineering, University of Leeds.
  74. Analysis of contact mechanics for composite cushion knee joint replacements. Year Published: 1998
  75. School of Mechanical Engineering, University of Leeds.
  76. Prediction of transient lubricating film thickness in knee prostheses with compliant layers. Year Published: 1998
  77. Department of Mechanical and Manufacturing Engineering, University of Bradford.
  78. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Year Published: 1999
  79. Department of Mechanical and Medical Engineering, University of Bradford, UK.
  80. A general elastohydrodynamic lubrication analysis of artificial hip joints employing a compliant layered socket under steady state rotation. Year Published: 2004
  81. School of Engineering, Design and Technology, University of Bradford, Bradford, UK.
  82. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses. Year Published: 2004
  83. School of Engineering Design and Technology, University of Bradford, Bradford, UK.
  84. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants. Year Published: 2005
  85. School of Mechanical Engineering, University of Leeds, Leeds, UK.
  86. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants. Year Published: 2006
  87. Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK.
  88. Metal-on-metal hip joint tribology. Year Published: 2006
  89. School of Mechanical Engineering, The University of Leeds, Leeds, UK. DDryedale@aol.com
  90. Deformation of press-fitted metallic resurfacing cups. Part 2: Finite element simulation. Year Published: 2006
  91. Division of Bioengineering, National University of Singapore, Singapore.
  92. Effect of ultra-high molecular weight polyethylene thickness on contact mechanics in total knee replacement. Year Published: 2006
  93. Trauma and Orthopaedics, Countess of Chester Hospital, Liverpool Road, Chester, UK. mujdeen@yahoo.co.uk
  94. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Year Published: 2007
  95. Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK.
 

Molecular Station USER Menu

Welcome to Molecular Station!

You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

Already registered? Login now below.

User Name:

Password:

Already registered and Forgot your password? Click below to recover it.

Recover Lost Password

Join now - it's fast and free!

Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

Research Terms of Usage and Disclaimer
Home
Features

Protocols

DNA Forum

Science Forum

DNA Forum
Biology Forum

Science News


[CaRP] XML error: Invalid document end at line 2

For more click here:Science News