Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Abstract Text:

    r filipoR Filipo,p manciniP Mancini,v panebiancoV Panebianco,m viccaroM Viccaro,e covelliE Covelli,v vergariV Vergari,r passarielloR Passariello,

    Conclusion. The image quality of 64-MDCT provided excellent definition of the fine osseous structures and individual electrode contacts. Evaluation of electrode distances revealed a more focused stimulation for the Helix contacts, with better optimization of pulse width and frequency of stimulation. Objectives. A multi-slice CT scan was performed postoperatively to evaluate electrode distance from the modiolus and variability of fitting parameters (M level) for two different types of cochlear implant electrode carriers, CII and 90K implants with 1J and Helix electrode carriers. Materials and methods. The electrode's position in different cochlear implant (CI) electrodes, Advanced Bionics 90K 1J and Helix, was assessed postoperatively in 20 adult patients by means of a 64-MDCT scanner. Axial, coronal, and oblique 0.3 mm multiplanar reconstructions (MPRs) were obtained and datasets were analyzed to assess the intracochlear position and distance from the surface of the electrodes to the bony edge of the modiolus. Patients' fitting characteristics were gathered at the time the CT was performed and correlated to intracochlear measurements. Results. Determination of contact distances confirmed smaller average values for the Helix at the apex and medial segments. Helix electrodes were closer to the modiolus in all segments. Likewise, M level determination showed lower values for the Helix carrier, confirming a more focused stimulation and better optimization of pulse width and frequency of stimulation.

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Publishing Authors By Initials

    r filipoR Filipo,p manciniP Mancini,v panebiancoV Panebianco,m viccaroM Viccaro,e covelliE Covelli,v vergariV Vergari,r passarielloR Passariello,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Acta oto-laryngologica

    VOLUME: 128

    Page Numbers: 291-6

    Journal Abbreviation: Acta Otolaryngol.

    ISSN: 0001-6489

    DAY: 15

    MONTH: Feb

    YEAR: 2008

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 370354

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants.

    AFFILIATION: Dipartimento di Neurologia ed Otorinolaringoiatria, Universita di Roma La Sapienza, Policlincio Umberto I, Rome, Italy.

    Country: Norway

    Norway Research PublicationNorway Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Acta Otolaryngol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News