Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study.

Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Abstract Text:

    v m rungeV M Runge,j e kirschJ E Kirsch,j w wellsJ W Wells,c e woolfolkC E Woolfolk,

    OBJECTIVE. The purpose of this study was to determine whether cerebral perfusion could be assessed with a conventional 1.5-T MR imaging system by applying a steady-state free-precession (SSFP) technique during bolus IV injection of contrast material (gadoteridol). Normal and abnormal perfusion states and the effect of the dose of contrast material were studied in cats. MATERIALS AND METHODS. Nine healthy anesthetized cats were imaged after administration of 0.5 mmol/kg (n = 5), 0.25 mmol/kg (n = 2), and 0.1 mmol/kg (n = 2) of gadoteridol. Six cats with an acute infarct of the middle cerebral artery (five cats 10 min after and one cat 1 hr after vessel occlusion) were evaluated at a dose of 0.5 mmol/kg. The middle cerebral artery was ligated in each instance by use of a snare placed around the vessel during surgery, which was performed via a transorbital approach. Each animal was imaged with spin-echo T2-weighted (3000/45,90 [TR/TE]) and T1-weighted (500/10) techniques before contrast material was injected. SSFP images (12/18, 80 degrees tip angle) were acquired sequentially (each with a 1-sec acquisition time and no interimage delay) immediately before and for 45 sec after IV injection of a bolus of gadoteridol. RESULTS. The first-pass effect in both normal gray and white matter was dose dependent, with a greater magnitude of change seen at higher doses of contrast material. A 55% decrease in signal intensity of normal peripheral gray matter was observed during the first pass after bolus injection of 0.5 mmol/kg gadoteridol, compared with a 23% decrease and a 17% decrease at doses of 0.25 and 0.1 mmol/kg, respectively. High temporal (one image per second) and spatial (1.5 x 1.5 x 6.0 mm) resolution was achieved, with sufficient sensitivity that both visual and statistical differentiation of normal and abnormal gray and white matter was possible. Ten minutes after vessel occlusion, the change in signal intensity during the first pass was 45 +/- 5% and 27 +/- 9% for normal central gray and white matter, respectively, as compared with 20 +/- 2% and 11 +/- 5% for ischemic central gray and white matter, respectively. CONCLUSION. Cerebral perfusion can be assessed on conventional 1.5-T MR imaging systems by combining high-dose IV bolus injection of contrast material (in this instance, using gadoteridol) with dynamic SSFP imaging.

    Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Publishing Authors By Initials

    vm rungeVM Runge,je kirschJE Kirsch,jw wellsJW Wells,ce woolfolkCE Woolfolk,

    For similar investigative techniques: perfusion research abstracts see: investigative techniques: perfusion research

    PUBMED ID PMID:

    MEDLINE DATE:

    Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJR. American journal of roentgenology

    VOLUME: 160

    Page Numbers: 593-600

    Journal Abbreviation:

    ISSN: 0361-803X

    DAY: 15

    MONTH: Mar

    YEAR: 1993

    Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 7708173

    Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Keywords Mesh Terms:

    KEYWORDS: Perfusion

    MESH TERMS: diagnostic use

    Chemical & Substance for Abstract: Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study. Information

    Substance Name: Gadolinium

    Registry Number: 7440-54-2

    Grant and Affiliation Information for Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study.

    AFFILIATION: University of Kentucky Magnetic Resonance Imaging and Spectroscopy Center, Lexington 40536-0098.

    Country: UNITED STATES

    UNITED STATES Research PublicationUNITED STATES Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJR Am J Roentgenol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Assessment of cerebral perfusion by first-pass, dynamic, contrast-enhanced, steady-state free-precession MR imaging: an animal study Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News