Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard.

Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Abstract Text:

    r h wuR H Wu,r linR Lin,h liH Li,z w xiaoZ W Xiao,h b raoH B Rao,w h luoW H Luo,g guoG Guo,k huangK Huang,x g zhangX G Zhang,z j langZ J Lang,

    The metabolite ratios had been employed in the field of MR spectroscopy (MRS) for a long period. The main drawback of metabolite ratio is that ratio results are not comparable with absolute metabolite concentration in vivo. The purpose of this study was to examine the accuracy of noninvasive quantification of brain N-acetylaspartate (NAA) concentrations using previously reported MR external standard method. Eight swine were scanned on a GE 1.5 T scanner with a standard head coil. The external standard method was utilized with a sphere filled with NAA, GABA, glutamine, glutamate, creatine, choline chloride, and myo-inositol. The position resolved spectroscopy (PRESS) sequence was used with TE=135 msec, TR=1500 msec, and 128 scan averages. The analysis of MRS was done with SAGE/IDL program. In vivo NAA concentration was obtained using the equation S=N * e(-TE/T2) * [1-e(-TR/T1). In vitro NAA concentration was measured by high performance liquid chromatography (HPLC). In the MRS group, the mean concentration of NAA was 10.03 plusmn 0.74 mmol/kg. In the HPLC group, the mean concentration of NAA was 9.22 plusmn 0.55 mmol/kg. There was no significant difference between the two groups (p = 0.46). However, slightly higher value was observed in the MRS group (7/8 swine), compared with HPLC group. The range of differences was between 0.02~2.05 mmol/kg. MRS external reference method could be more accurate than internal reference method. 1H MRS does not distinguish between N-acetyl resonance frequencies and other N-acetylated amino acids.

    Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Publishing Authors By Initials

    rh wuRH Wu,r linR Lin,h liH Li,zw xiaoZW Xiao,hb raoHB Rao,wh luoWH Luo,g guoG Guo,k huangK Huang,xg zhangXG Zhang,zj langZJ Lang,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Conference proceedings : ... Annual International

    VOLUME: 2

    Page Numbers: 1396-9

    Journal Abbreviation:

    ISSN: 1557-170X

    DAY: 6

    MONTH: 02

    YEAR: 2005

    Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 101243413

    Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard.

    AFFILIATION: Med. Imaging & Central Lab., Shantou Univ. Med. Coll.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Conf Proc IEEE Eng Med Biol So

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Accuracy of noninvasive quantification of brain NAA concentrations using PRESS sequence: verification in a swine model with external standard Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News