Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry.

Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Abstract Text:

    tao zhouTao Zhou,motian zhaoMotian Zhao,jun wangJun Wang,hai luHai Lu,

    Two enriched isotopes, 99.94 at.% (56)Fe and 99.90 at.% (54)Fe, were blended under gravimetric control to prepare ten synthetic isotope samples whose (56)Fe isotope abundances ranged from 95% to 20%. For multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements typical polyatomic interferences were removed by using Ar and H(2) as collision gas and operating the MC-ICP-MS system in soft mode. Thus high-precision measurements of the Fe isotope abundance ratios were accomplished. Based on the measurement of the synthetic isotope abundance ratios by MC-ICP-MS, the correction factor for mass discrimination was calculated and the results were in agreement with results from IRMM014. The precision of all ten correction factors was 0.044%, indicating a good linearity of the MC-ICP-MS method for different isotope abundance ratio values. An isotopic reference material was certified under the same conditions as the instrument was calibrated. The uncertainties of ten correction factors K were calculated and the final extended uncertainties of the isotopic certified Fe reference material were 5.8363(37) at.% (54)Fe, 91.7621(51) at.% (56)Fe, 2.1219(23) at.% (57)Fe, and 0.2797(32) at.% (58)Fe. Copyright (c) 2008 John Wiley & Sons, Ltd.

    Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Publishing Authors By Initials

    t zhouT Zhou,m zhaoM Zhao,j wangJ Wang,h luH Lu,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Rapid communications in mass spectrometry : RCM

    VOLUME: 22

    Page Numbers: 717-20

    Journal Abbreviation: Rapid Commun. Mass Spectrom.

    ISSN: 0951-4198

    DAY: 18

    MONTH: 02

    YEAR: 2008

    Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8802365

    Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry.

    AFFILIATION: National Institute of Metrology, Beijing 100013, China.

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Rapid Commun Mass Spectrom

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Absolute measurements and certified reference material for iron isotopes using multiple-collector inductively coupled mass spectrometry Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News