A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry.

A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Abstract Text:

    myoung hwan choiMyoung Hwan Choi,tzu-jen kaoTzu-Jen Kao,david isaacsonDavid Isaacson,gary j saulnierGary J Saulnier,jonathan c newellJonathan C Newell,

    The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system.

    A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Publishing Authors By Initials

    mh choiMH Choi,tj kaoTJ Kao,d isaacsonD Isaacson,gj saulnierGJ Saulnier,jc newellJC Newell,

    For similar diagnosis: diagnostic techniques and procedures: diagnostic imaging: tomography research abstracts see: diagnosis: diagnostic techniques and procedures: diagnostic imaging: tomography research

    PUBMED ID PMID:

    MEDLINE DATE:

    A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Journal Published:

    PUBLICATION TYPE: Research Support, U.S. Gov't,

    Journal: IEEE transactions on bio-medical engineering

    VOLUME: 54

    Page Numbers: 700-10

    Journal Abbreviation:

    ISSN: 0018-9294

    DAY: 3

    MONTH: Apr

    YEAR: 2007

    A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 12737

    A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Keywords Mesh Terms:

    KEYWORDS: Tomography

    MESH TERMS: methods

    Chemical & Substance for Abstract: A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry.

    AFFILIATION: Department of Electrical and Electronics Engineering, Kangwon National University, 192-1, Hyoza 2 dong, Chunchon, Kangwondo, Korea. mhchoi@kangwon.ac.kr

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NIBIB

    GRANT: 1 R01 EB000456-01

    ACRONYM: EB

    MEDLINETA: IEEE Trans Biomed Eng

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News