A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap.

A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Abstract Text:

    xiaorong liangXiaorong Liang,hongling hanHongling Han,yu xiaYu Xia,scott a mcluckeyScott A McLuckey,

    A pulsed triple ionization source, using a common atmosphere/vacuum interface and ion path, has been developed to generate different types of ions for sequential ion/ion reaction experiments in a linear ion trap-based tandem mass spectrometer. The triple ionization source typically consists of a nano-electrospray emitter for analyte formation and two other emitters, an electrospray emitter and an atmospheric pressure chemical ionization emitter or a second nano-electrospray emitter for formation of the two different reagent ions. The three emitters are positioned in a parallel fashion close to the sampling orifice of the tandem mass spectrometer. The potentials applied to each emitter are sequentially pulsed so that desired ions are generated separately in time and space. Sequential ion/ion reactions take place after analyte ions of interest and different set of reagent ions are sequentially injected into a linear ion trap, where axial trapping is effected by applying an auxiliary radio frequency voltage to the end lenses. The pulsed triple ionization source allows independent optimization of each emitter and can be readily coupled to any atmospheric pressure ionization interface with no need for instrument modifications, provided the potentials required to transmit the ion polarity of interest can be synchronized with the emitter potentials. Several sequential ion/ion reactions examples are demonstrated to illustrate the analytical usefulness of the triple ionization source in the study of gas-phase ion/ion chemistry.

    A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Publishing Authors By Initials

    x liangX Liang,h hanH Han,y xiaY Xia,sa mcluckeySA McLuckey,

    For similar proteins: ubiquitins: ubiquitin research abstracts see: proteins: ubiquitins: ubiquitin research

    PUBMED ID PMID:

    MEDLINE DATE:

    A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Journal Published:

    PUBLICATION TYPE: Research Support, Non-U.S. Gov

    Journal: Journal of the American Society for Mass Spectrome

    VOLUME: 18

    Page Numbers: 369-76

    Journal Abbreviation: J. Am. Soc. Mass Spectrom.

    ISSN: 1044-0305

    DAY: 13

    MONTH: 11

    YEAR: 2006

    A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 9010412

    A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Keywords Mesh Terms:

    KEYWORDS: Ubiquitin

    MESH TERMS: chemistry

    Chemical & Substance for Abstract: A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap. Information

    Substance Name: Bradykinin

    Registry Number: 58-82-2

    Grant and Affiliation Information for A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap.

    AFFILIATION: Department of Chemistry, Purdue University, West Lafayette, Indiana 47907-2084, USA.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY: United States NIGMS

    GRANT: GM 45372

    ACRONYM: GM

    MEDLINETA: J Am Soc Mass Spectrom

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    A pulsed triple ionization source for sequential ion/ion reactions in an electrodynamic ion trap Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News