Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries.

A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Abstract Text:

    piotr skworcowPiotr Skworcow,john a millsJohn A Mills,olivier c l haasOlivier C L Haas,keith j burnhamKeith J Burnham,piotr skworcowPiotr Skworcow,john a millsJohn A Mills,olivier c l haasOlivier C L Haas,keith j burnhamKeith J Burnham,piotr skworcowPiotr Skworcow,john a millsJohn A Mills,olivier c l haasOlivier C L Haas,keith j burnhamKeith J Burnham,

    In this paper a new method is proposed to quantify and reduce the radiation beam position uncertainty due to the radiotherapy treatment machine gantry deflection. A new tool has been designed and manufactured to provide the means to measure the alignment of the collimator axis and of the beam central axis in space, using the NDI Polaris optical tracking system and Gafchromic(R) films. The tool can be mounted onto the accessory tray of the linacs from different manufacturers. The approach has been demonstrated with measurements of the mechanical isocentre being performed on ten linacs from three major manufacturers at four clinical sites. Measurements of the radiation isocentre were performed on a single linac. The collimator axis trajectory is modelled using a vector-end effector in order to provide more information than standard mechanical assessment methods. The method uses a mathematical optimization technique to calculate the position of the mechanical isocentre and the 'size' of the collimator axes intersection locus. Deviations of the collimator axes from the isocentre are expressed in terms of systematic and random error. The effects of measurement uncertainties are evaluated both via simulations and experimentally. The use of optical tracking and optimization techniques combined with an operator-induced measurement error compensation algorithm leads to a faster measurement of the mechanical isocentre (20 min for 24 angles) and eliminates operator-induced uncertainties. The uncertainty of the measurement of the mechanical isocentre was between 40 microm and 70 microm in terms of standard deviation. For some of the linacs assessed, the mechanical isocentre obtained using a standard approach with an adjustable pointer was displaced by over 1 mm from that found with the proposed method. The radii of the collimator axes intersection locus found with the proposed method were between 0.4 mm and 0.72 mm for the linacs assessed. Film measurement revealed a misalignment of the mechanical isocentre and the radiation isocentre by 0.4 mm. The proposed method potentially enables a reduction of the beam position uncertainty. This may be achieved at the planning stage by compensating for the identified systematic collimator axes deviations which were found to be reproducible. The method also creates a potential for using different setup margins independently for each axis and for each gantry angle, calculated specifically for a given linac.

    A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Publishing Authors By Initials

    p skworcowP Skworcow,ja millsJA Mills,oc haasOC Haas,kj burnhamKJ Burnham,p skworcowP Skworcow,ja millsJA Mills,oc haasOC Haas,kj burnhamKJ Burnham,p skworcowP Skworcow,ja millsJA Mills,oc haasOC Haas,kj burnhamKJ Burnham,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Physics in medicine and biology

    VOLUME: 52

    Page Numbers: 7109-24

    Journal Abbreviation:

    ISSN: 0031-9155

    DAY: 16

    MONTH: 11

    YEAR: 2007

    A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 401220

    A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries.

    AFFILIATION: Control Theory and Applications Centre, Coventry University, CV1 5ED, UK.

    Country: England

    England Research PublicationEngland Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Phys Med Biol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News