Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

3.3F catheter/sheath system for use in diagnostic neuroangiography.

3.3F catheter/sheath system for use in diagnostic neuroangiography. Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • 3.3F catheter/sheath system for use in diagnostic neuroangiography. Abstract Text:

    hiro kiyosueHiro Kiyosue,mika okaharaMika Okahara,hirofumi nagatomiHirofumi Nagatomi,takaharu nakamuraTakaharu Nakamura,shuichi tanoueShuichi Tanoue,hiromu moriHiromu Mori,

    BACKGROUND AND PURPOSE: Although neuroangiography remains the criterion standard standard for the detection of and surgical/interventional planning for cerebrovascular diseases, it usually requires that patients be confined to bed rest for several hours after angiography to prevent local complications. Decreasing catheter size has reduced the risk of hemorrhagic complications associated with early ambulation after angiography. For this study, we prospectively evaluated the clinical feasibility of a 3.3F catheter/sheath system for selective neuroangiography. METHODS: One hundred seventeen consecutive patients (49 men, 68 women; age range, 18-83 years; mean age, 56.9 years) underwent selective neuroangiography using 3.3F catheters. The exclusion criteria for this study included a subsequent surgical/neurointerventional procedure performed within 18 hours and necessity of arch aortography, which is routinely performed for the first examination of patients with ischemic cerebrovascular diseases. The procedure was evaluated prospectively in terms of success rate, compression time of the arterial puncture site, and periprocedural complications. RESULTS: Selective catheterization of the intended arteries was performed in 99% of the carotid arteries and 97.4% of the vertebral arteries. No neurologic complications or local hemorrhagic complications were observed. Manual compression time after the procedure ranged from 3 to 7 minutes (mean, 3.7 minutes), and patient bed rest after the procedure ranged from 2 to 3 hours (mean, 2.04 hours). CONCLUSION: Selective neuroangiography with a 3.3F catheter/sheath system is feasible and enables early ambulation in selected patients.

    3.3F catheter/sheath system for use in diagnostic neuroangiography. Publishing Authors By Initials

    h kiyosueH Kiyosue,m okaharaM Okahara,h nagatomiH Nagatomi,t nakamuraT Nakamura,s tanoueS Tanoue,h moriH Mori,

    For similar investigative techniques: epidemiologic methods: epidemiologic study characteristics as topic: epidemiologic studies: cohort studies: longitudinal studies: prospective studies research abstracts see: investigative techniques: epidemiologic methods: epidemiologic study characteristics as topic: epidemiologic studies: cohort studies: longitudinal studies: prospective studies research

    PUBMED ID PMID:

    MEDLINE DATE:

    3.3F catheter/sheath system for use in diagnostic neuroangiography. Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: AJNR. American journal of neuroradiology

    VOLUME: 23

    Page Numbers: 711-5

    Journal Abbreviation:

    ISSN: 0195-6108

    DAY: 14

    MONTH: Apr

    YEAR: 2002

    3.3F catheter/sheath system for use in diagnostic neuroangiography. Information

    Number of References:

    LANGUAGE: eng

    NlmUniqueID: 8003708

    3.3F catheter/sheath system for use in diagnostic neuroangiography. Keywords Mesh Terms:

    KEYWORDS: Prospective Studies

    MESH TERMS: radiography

    Chemical & Substance for Abstract: 3.3F catheter/sheath system for use in diagnostic neuroangiography. Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for 3.3F catheter/sheath system for use in diagnostic neuroangiography.

    AFFILIATION: Department of Radiology, Nagatomi Neurosurgical Hospital, Japan.

    Country: United States

    United States Research PublicationUnited States Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: AJNR Am J Neuroradiol

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    33F catheter/sheath system for use in diagnostic neuroangiography Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News