Special Feature

User Panel

My Panel

My Panel

Bookmark Science Articles

Recent News
Bookmark / Share This Science Site

[Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome]

[Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Research Abstract Details 

Research Abstract Table of Contents

Jump to the:

  • Abstract Text of This Paper
  • Journal Published
  • MeSH Keywords of This Abstract
  • Chemicals and Substances Used in this Paper
  • Grants and Granting Agency of this Research
  • Database Accession Numbers Used in this Paper
  • Related Papers
  • Related Research Tags
  • Rate this Research Paper
  • [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Abstract Text:

    feng-chun zhangFeng-Chun Zhang,li liuLi Liu,dong xuDong Xu,

    OBJECTIVE: To investigate the correlation of anti-60 000 SSA antibody and anti-52 000 SSA antibody with systemic lupus erythematosus (SLE) and Sjögren's syndrome (SS). METHODS: Western blotting against purified 60 000 SSA antigenic polypeptide and 52 000 SSA antigenic polypeptide were done to detect the anti-60 000 SSA and anti-52 000 SSA antibodies in 59 serum samples positive in anti-SSA antibodies, among which 44 samples were from SLE patients and 15 samples from SS patients. RESULT: There was no significant difference in positive rate of anti-60 000 SSA antibodies between the SLE and pSS patients (P > 0.05). But the sole positive rate of anti-60 000 SSA antibodies of the SLA patients was 39.47% (15/38), significantly higher than that of the primary SS (pSS) patients ((6.67%, 1/15, P < 0.05). The positive rate of anti-52 000 SSA antibodies of the pSS patients was 93.33% (14/15), significantly higher than that of the SLE patients (23/38, 60.53%, P < 0.05). There was no significant differences in positive rates of anti-60 000 SSA antibodies and anti-52 000 SSA antibodies between the secondary SS (sSS) and pSS patients (P > 0.05). CONCLUSION: The pSS patients mainly present anti-52 000 antibodies and with a very low sole anti-60 000 SSA antibody positive rate. Sole positivity of anti-52 000 SSA antibodies maybe correlated with pSS and is not a strong implication for the diagnosis of sSS. Sole positive anti-60000 SSA antibodies rate can be seen maily in SLE.

    [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Publishing Authors By Initials

    fc zhangFC Zhang,l liuL Liu,d xuD Xu,

    For similar abstracts research abstracts see: abstracts research

    PUBMED ID PMID:

    MEDLINE DATE:

    [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Journal Published:

    PUBLICATION TYPE: Journal Article

    Journal: Zhonghua yi xue za zhi

    VOLUME: 87

    Page Numbers: 7-10

    Journal Abbreviation: Zhonghua Yi Xue Za Zhi

    ISSN: 0376-2491

    DAY: 2

    MONTH: Jan

    YEAR: 2007

    [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Information

    Number of References:

    LANGUAGE: chi

    NlmUniqueID: 7511141

    [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Keywords Mesh Terms:

    KEYWORDS:

    MESH TERMS:

    Chemical & Substance for Abstract: [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome] Information

    Substance Name:

    Registry Number:

    Grant and Affiliation Information for [Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome]

    AFFILIATION: Department of Rheumatology, Peking Union Medical College Hospital, Peking Union Medical College, Beijing, China.

    Country: China

    China Research PublicationChina Research Publication

    AGENCY:

    GRANT:

    ACRONYM:

    MEDLINETA: Zhonghua Yi Xue Za Zhi

    REFSOURCE:

    DATABASENAME:

    ACCESSION NUMBER:

    Number Hits: 0

    Correlation of anti-60000 SSA antibody and anti-52000 SSA antibody with systemic lupus erythematosus and Sjögren's syndrome Related Publications

     

    Molecular Station USER Menu

    Welcome to Molecular Station!

    You have to register before you can post on our forums or use our advanced features. Register Now! Its Free and Fast!

    Already registered? Login now below.

    User Name:

    Password:

    Already registered and Forgot your password? Click below to recover it.

    Recover Lost Password

    Join now - it's fast and free!

    Molecular Station is THE largest network of researchers, scientists and science lovers anywhere!

    Research Terms of Usage and Disclaimer
    Home
    Features

    Protocols

    DNA Forum

    Science Forum

    DNA Forum
    Biology Forum

    Science News


    [CaRP] XML error: Invalid document end at line 2

    For more click here:Science News