Immunostaining thin layer chromatograms TLC is a very sensitive detection technique of functionally active carbohydrate ligands of protein receptors. Carbohydrate structures are detected in glycolipids from complex mixtures of molecules extracted from the relevant target tissue. Proteins analyzed can be antibodies, chimeric Ig proteins, selectins, lectins, toxins, and other carbohydrate binding proteins. John L. Magnani~GlycoTech Corporation, Rockville, Maryland - [Read Immunostaining Thin Layer Chromatograms Of Glycolipids]
Many proteins and molecules promote cell adhesion including several cell surface carbohydrate binding proteins. Cell adhesion measurements on 96-well microtiter plate format are difficult due to the shear forces generated by washing the wells. The protocol here introduces the use of a liquid-filled wash chamber that separates unbound cells by gravity. This eliminates uncontrolled shear forces and passage of adherent cells through a liquid/air interface. John L. Magnani~GlycoTech Corporation. - [Read Measurement of Cell Adhesion Under Static Conditions]
Solvent partition protocol allows the isolation of gangliosides from small samples and from samples where ganglioside concentrations are low, especially relative to the concentration of potentially contaminating proteins and other large molecular weight species. Stephan Ladisch Director, Center for Cancer and Transplant Biology, Children's National Medical Center, Washington, D.C. - [Read A Method for Micro-Scale Isolation and Purification of Gangliosides]
The method allows the detection and quantification of glycosyltransferase activity using an ELISA-based procedure and carbohydrate-specific monoclonal antibodies. Avoids the use of radiolabeled substrates. Bruce A. Macher~Professor of Chemistry and Biochemistry, San Francisco State University, San Francisco, CA - [Read A Sensitive ELISA-Based Assay for Glycosyltransferases]
High performance liquid affinity chromatography (HPLAC) is a useful procedure to investigate he interactions between carbohydrate binding protein and their ligands. Technical requirements are similar to conventional HPLC. HPLAC can screen and separate natural ligands from complex biological mixtures. WeiTong Wang~GlycoTech Corporation, Rockville, Maryland - [Read Analysis of Oligosaccharide Ligands by High Performance Liquid Affinity Chromatography]
Protocol detects specific cell adhesion to glycolipids resolved on TLC plates. Carbohydrate-Specific Adhesion of Intact Cells to Resolved Glycolipids on TLC Plates. Ronald L. Schnaar~Professor, Johns Hopkins University Medical School, Baltimore, Maryland. Glycotech. - [Read Carbohydrate-Specific Adhesion of Intact Cells to Resolved Glycolipids on TLC Plates]
Deglycosylation steps are different with every glycoprotein and must be determined empirically (Methods in Enzymology, 1994, 230: 44-57). A typical test reaction of human transferrin is described.
T.H. Plummer, Jr. and A.L. Tarentino, Department of Biochemistry, New York State Department of Health, Wadsworth Center for Laboratories and Research, Albany, New York - [Read Deglycosylation of Glycoproteins Using Endoglycosidases]
Flow assays offer visualization of cell adhesion under wall shear stress. Visualization of the different events of cell adhesion can be quantified by selective image acquisition and subsequent image processing. Flow assays are suited for adhesive events which occur very rapidly in a time scale shorter than that of most static adhesion assays. Also, events subsequent to the initial events can be studied such as cell stabilization and spreading giving some insight into the kinetics of cell-cell. - [Read Dynamic Flow Assay for Cell Adhesion in a Parallel Plate Flow Chamber]
Flow assays allow visualization of cell adhesion under well-defined wall shear stress. Visualization of the events of cell adhesion are quantified by selective image acquisition and image processing. Events subsequent to the initial events can be studied such as cell stabilization and spreading. John T. Patton~GlycoTech Corporation, Rockville, Maryland - [Read Dynamic Flow Assay in a Parallel Plate Flow Chamber]
Indirect method measuring immunofluorescence coupled to second antibody. Best for membrane antigens in addition to intra- and extracellular antigens, may be applied to frozen tissue sections, to cells in suspension, and to cells attached to glass slides or coverslips. Tadashi Tai~Head, Department of Tumor Immunology, The Tokyo Metropolitan Institute of Medical Science, Tokyo, Japan - [Read Immunohistochemistry using Anti-Ganglioside Antibodies]
This protocol introduces the use of a liquid-filled wash chamber that separates unbound cells by gravity thereby eliminating uncontrolled shear forces and passage of adherent cells through a liquid/air interface. The cells are loaded with a fluorescent dye (6-carboxyfluorescein diacetate) for detection although other methods such as radioactive labels malabels may be used. This protocol is also useful for assaying molecules that promote or inhibit cell adhesion. - [Read Protocol for Measurement of Cell Adhesion Under Static Conditions]