Methanol-Chloroform Precipitation of Proteins. A procedure for precipitating proteins from solution, including detergent solutions, is from Wessel and Flügge (1984). Univ. Virginia. - [Read Methanol-Chloroform Precipitation of Proteins]
Millipore's ZipTip Protocol. Intended for purifying and concentrating femtomoles to picomoles of protein, peptide or oligonucleotide samples prior to analysis, providing better data quality. Millipore. - [Read Millipore's ZipTip Protocol]
Colloidal coomassie blue staining, Destaining, Reduction/Alkylation, Peptide extraction For MALDI-MS analysis and For MALDI-MS analysis protocols and methods. Institut Curie Paris. - [Read Proteomic protocols and Peptide Extraction]
Protocols for Mass Spectrometry Analysis Preparation. Preparing gel slices for PMF or MS/MS , mass spec data interpretation, Submitting proteins in solution, Interpretation of LC-MS/MS data. BMS MASS SPECTROMETRY AND PROTEOMICS FACILITY - [Read Protocols for Mass Spectrometry Analysis Preparation]
MALDI Matrices. Commonly used MALDI matrices for analysis of peptides, proteins, carbohydrates, and nucleic acids using 337 nm or 355 nm UV lasers. All matrices can be used for sample preparation using the Dried Droplet Method whereas only matrices solubl - [Read MALDI Matrices]
Fast Evaporation Method for MALDI sample preparation protocol. Inserting into MALDI mass spectrometer and acquiring a spectrum. EMBL Bioanalytical Research Group. Wilm. - [Read MALDI Sample Preparation - Fast Evaporation Method]
Dried droplet Sample Preparation for MALDI.The discovery of this method allowed the application of laser desorption to proteins [2]. Drying a droplet of a protein/matrix solution remains the favorite method of most MALDI practitioners. Protocol for dried - [Read Dried droplet Sample Preparation for MALDI]
Deamidation in Proteins and Peptides. Informational page by Glen Teshima. RPLC, HIC, Peptide mapping of proteolytic digests (LC-MS), Protein carboxyl methyltransferase (PIMT). - [Read Deamidation in Proteins and Peptides]
This method of sample preparation produces a uniform layer of very small crystals on the mass spectrometer's sample stage that are mechanically well adhered to the substrate. It is a variant of the dried droplet method. PROWL - [Read Polycrystalline thin films Sample Preparation Protocol MALDI]
This sample preparation method is a direct replacement for the dried droplet technique. It produces more uniform samples than the dried-droplet technique and the crystals are better adhered to the sample stage’s surface. MALDI Sample preparation. PROWL - [Read Seeded films (Vorm-Roepstorff) MALDI Protocol]